-9-
No. PF
※※
-OMK0004-F
Adjustment and Operation
Do not short-circuit the load.
When the product load is short circuit, generated excess current lead to cause the damage of the product.
Supply the power when there is no flow.
If using the product to detect very small flow rates, warm up the product for 10 to 15 minutes first.
There will be a drift on the analogue output of approximate
2 to 30% immediately after supply is turn on. Within 10
minutes.
Check regulators and flow adjustment valves before introducing the fluid.
Pay attention to the response speed.
When the sensor is used to check the suction, the response speed of the sensor might be delayed due to the
piping volume between the suction nozzle and sensor. Therefore, take measures to reduce the piping volume.
Maintenance
Perform regular maintenance and inspections.
There is a risk of unexpected malfunction.
Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of
air before performing maintenance.
There is a risk of unexpected malfunction.
Perform drainage regularly.
If condensate enters the secondary side, it can cause operating failure of pneumatic equipment.
Do not use solvents such as benzene, thinner etc. to clean the product.
They could damage the surface of the body and erase the markings on the body.
Use a soft cloth to remove stains.
For heavy stains, use a cloth lightly dampened with diluted neutral detergent, then wipe up any residue with a dry
cloth.