background image

-2- 

 

No. PF

※※

-OMK0004-F

 

 

Safety Instructions

 

 
These safety instructions are intended to prevent hazardous situations and/or equipment damage.

 

These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger".

 

They are all important notes for safety and must be followed in addition to International Standards 
(ISO/IEC)

*1)

, and other safety regulations.

 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

 

ISO 4413: Hydraulic fluid power -- General rules relating to systems.

 

IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)

 

ISO 10218: Manipulating industrial robots -Safety.

 

etc.

 

 

Caution

 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could 

result in minor or moderate injury.

 

 

Warning

 

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, 

could result in death or serious injury.

 

 

Danger

 

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will 

result in death or serious injury.

 

 

Warning

 

1. The compatibility of the product is the responsibility of the person who designs the 

equipment or decides its specifications.

 

Since the product specified here is used under various operating conditions, its compatibility with specific 
equipment must be decided by the person who designs the equipment or decides its specifications 
based on necessary analysis and test results. 
The expected performance and safety assurance of the equipment will be the responsibility of the 
person who has determined its compatibility with the product. 
This person should also continuously review all specifications of the product referring to its latest catalog 
information, with a view to giving due consideration to any possibility of equipment failure when 
configuring the equipment.

 

2. Only personnel with appropriate training should operate machinery and equipment.

 

The product specified here may become unsafe if handled incorrectly.

 

The assembly, operation and maintenance of machines or equipment including our products must be 
performed by an operator who is appropriately trained and experienced.

 

3. Do not service or attempt to remove product and machinery/equipment until safety is 

confirmed.

 

1. The inspection and maintenance of machinery/equipment should only be performed after measures to 

prevent falling or runaway of the driven objects have been confirmed.

 

2. When the product is to be removed, confirm that the safety measures as mentioned above are 

implemented and the power from any appropriate source is cut, and read and understand the specific 
product precautions of all relevant products carefully. 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

 

4. Contact SMC beforehand and take special consideration of safety measures if the 

product is to be used in any of the following conditions.

 

1. Conditions and environments outside of the given specifications, or use outdoors or in a place 

exposed to direct sunlight. 

2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
other applications unsuitable for the standard specifications described in the product catalog.

 

3. An application which could have negative effects on people, property, or animals requiring special 

safety analysis.

 

4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using 

a mechanical protective function, and periodical checks to confirm proper operation. 

Summary of Contents for PFMV5 Series

Page 1: ...No PF OMK0004 F PRODUCT NAME Flow sensor MODEL Series Product Number PFMV5 ...

Page 2: ...s 2 Model Indication and How to Order 10 Summary of Product parts 12 Definition and terminology 13 Mounting and Installation 14 Installation 14 Piping 16 Wiring 17 Troubleshooting 18 Specifications 19 Specifications 19 Characteristics data 20 Dimensions 22 ...

Page 3: ... equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to remo...

Page 4: ... the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product due to the use of the v...

Page 5: ...t can result Verify the specifications before use Do not operate in an atmosphere containing flammable or explosive gases Fire or an explosion can result This product is not designed to be explosion proof Do not use the product for flammable fluid A fire or explosion can result Only air and N2 are applicable Do not use the product in a place where static electricity is a problem Otherwise it can c...

Page 6: ...ollows Circuit Class 2 of maximum 30 Vrms 42 4 V peak or less with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer The product is a UL approved product only if it has a mark on the body Use the specified voltage Otherwise failure or malfunction can result Insufficient supply voltage may not drive a load due to a voltage drop inside the product Verify the operating voltage of the loa...

Page 7: ...pecified part of the body with a spanner Hold the product body when handling to prevent damage failure or malfunction Any dust left in the piping should be flushed out by air blow before connecting the piping to the product Otherwise it can cause damage or malfunction Refer to the flow direction of the fluid indicated on the product label for installation and piping Do not mount the body with the ...

Page 8: ...Incorrect wiring can damage the product Do not perform wiring while the power is on Otherwise damage to the internal parts can result causing malfunction Do not route wires and cables together with power or high voltage cables Otherwise the product can malfunction due to interference or noise and surge voltage from power and high voltage cables Confirm proper insulation of wiring Poor insulation i...

Page 9: ... in the system Do not use the product in areas that are exposed to vibration or impact Otherwise failure or malfunction can result Do not use the product in the presence of a magnetic field This may lead to the malfunction of the product Prevent foreign matter such as wire debris from entering the product Otherwise failure or malfunction can result Do not use the product in areas subject to large ...

Page 10: ...ight be delayed due to the piping volume between the suction nozzle and sensor Therefore take measures to reduce the piping volume Maintenance Perform regular maintenance and inspections There is a risk of unexpected malfunction Turn off the power supply stop the supplied air exhaust the residual pressure and verify the release of air before performing maintenance There is a risk of unexpected mal...

Page 11: ... 10 No PF OMK0004 F Model Indication and How to Order ...

Page 12: ...he following part numbers Part number Description Remarks ZS 36 A1 1 station 2 L type brackets With mounting screws M3 x 15 L 2 pcs ZS 36 A2 2 station 2 L type brackets With mounting screws M3 x 25 L 2 pcs ZS 36 A3 3 station 2 L type brackets With mounting screws M3 x 35 L 2 pcs ZS 36 A4 4 station 2 L type brackets With mounting screws M3 x 45 L 2 pcs ZS 36 A5 5 station 2 L type brackets With moun...

Page 13: ...duct parts Item Description Piping port Connection port for piping Body The body of the product Mounting hole Used to mount the product on a DIN rail or directly to a panel Lead wire Lead wire to supply power and transmit output signals ...

Page 14: ...nge within which the product will meet all published specifications Operating temperature range The ambient temperature range within which the product will meet all published specifications P Part in contact with fluid A part that comes into physical contact with the fluid Pressure characteristic The amount of variation in the analogue output when the supply pressure is changed Proof pressure The ...

Page 15: ...mately 3 F S might be generated Install the product taking this into consideration Direct mounting Install the product using the M3 screws 2 pcs Bracket mounting Mount the bracket using the mounting screws M3 x 15 L supplied The required tightening torque is 0 32 0 02 Nm Install the product with bracket using the M4 screws 2 pcs or 4 pcs Bracket thickness is approximately 1 mm Refer to the dimensi...

Page 16: ...que is 0 32 0 02 Nm Mounting in series using the mounting brackets is not suitable for all models depending on which fitting type is used Install the product with bracket using the M4 screws 4 pcs Bracket thickness is approximately 1 mm Refer to the dimension drawing of the bracket page 22 for mounting hole dimensions ...

Page 17: ...piping size on the IN side of the sensor Use this product within the specified operating pressure and temperature ranges Use this product within the rated flow range Proof pressure is 500 kPa PFMV5 series recommended fitting list One Touch fitting Series KQ2 Type Tube dimension mm Port size Model Male Connector 4 M5 x 0 8 KQ2H04 M5 Hexagon socket head male connector KQ2S04 M5 Male elboe KQ2L04 M5 ...

Page 18: ...power supply When a switch mode power supply is connected to the product switching noise will be superimposed and the product specification can no longer be met This can be prevented by inserting a noise filter such as a line noise filter and ferrite core between the switch mode power supply and the product or by using a series power supply instead of a switch mode power supply Lead wire Colour Co...

Page 19: ...foreign matter has entered the flow passage 2 Check if there is foreign matter on the mesh Install a filter or mist separator on the IN side Mounting direction of the product and signal output direction do not match Check that the mounting direction of the product and the analogue voltage output direction are the same as the flow direction Mounting direction of the product analogue signal output d...

Page 20: ...e 0 to 50 o C no freezing or condensation Operating temp range Operating 0 to 50 o C Storage 10 to 60 o C no freezing or condensation Operating humidity range Operating storage 35 to 85 R H no condensation Withstand voltage 1000 VAC 1 min between battery and the body Insulation resistance 50 MΩ min at 500 VDC between terminals and case Standards CE UL CSA RoHS Port size M5 x 0 8 tightening torque ...

Page 21: ... 20 No PF OMK0004 F Characteristics data Analogue output characteristics Non linear output ...

Page 22: ... 21 No PF OMK0004 F Pressure loss Nozzle diameter and flow characteristics Approximate values Refer to catalog for details ...

Page 23: ... 22 No PF OMK0004 F Dimensions in mm PFMV5 PFMV5 L type bracket Mount on one side Mount on both sides ...

Page 24: ...ts revised in several places September 2016 F Contents revised in several places August 2018 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2011 2018 SMC Corporation All Rights Reserved ...

Reviews: