-27-
No.PF
※※
-OMS0002-B
■
[F 0] Reference condition/Unit selection function
Reference condition
Standard condition or normal condition can be selected.
Standard condition (ANR) and normal condition (NOR) are defined as follows:
Standard condition (ANR): 101.3 kPa, 20 °C, 65% RH
Normal condition (NOR): 101.3 kPa, 0 °C
Unit selection function
The selectable display units are L/min or CFM (ft
3
/min).
This setting is only available for models with the unit selection function.
: This function is not displayed for models without unit selection function.
<Operation>
Press the
or
button in function selection mode to display [F 0] on the main display.
[REF] and [the current set value] are displayed in turn on the sub display.
Press the
button.
Reference condition
[rEF] is displayed on the main display.
[The current set value] flashes on the sub display.
Press the
or
button to select.
Press the
button to set. Press the
button to set.
(Fixed to SI units) (Only for unit selection function)
Unit selection function
[Uni] is displayed on the main display.
[The current set value] flashes on the sub display.
Press the
or
button to select.
Press the
button.
[F 0] Setting of reference condition/Unit selection function completed.
Return to function selection mode.