background image

Doc. no. PAB-OM-H007-D 

 

 

 

 

 

 

 

 

 

PRODUCT NAME

 

 

Process Pump 

 

MODEL / Series / Product Number

 

 

PAF3410

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PAF3410

Page 1: ...Doc no PAB OM H007 D PRODUCT NAME Process Pump MODEL Series Product Number PAF3410...

Page 2: ...scription and function of individual port P 5 4 How to use P 5 to 6 5 Maintenance and check P 6 6 Specification and how to order P 7 to 8 7 Discharge capability P 9 to 10 8 Troubleshooting P 11 to 12...

Page 3: ...ent failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The ass...

Page 4: ...ts 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product...

Page 5: ...frigerating air dryer AM mist separator AMD micro mist separator PAF If the amount of foreign materials generated from air supply carbon powder etc is large mount super mist separator etc to reinforce...

Page 6: ...of individual port Suction port FLUID IN To suck transported fluid Connect suction piping Discharge port FLUID OUT To discharge fluid sucked inside the pump Connect discharge piping Air supply port A...

Page 7: ...dically If any abnormality or concern is seen stop the pump immediately and contact local supplier or SMC When touching the pump for maintenance put the protective tool such as glove which isn t affec...

Page 8: ...ir Supply Exhaust port Rc G NPT 1 4 Material Body wetted areas newPFA Diaphragm Seal PTFE Check valve newPFA PTFE Discharge flow rate 1 to 20L min Average discharge pressure 0 to 0 4MPa Air consumptio...

Page 9: ...ng type Fitting size In side Out side Symbol Thread style Symbol Style NIL Fitting type With silencer Operation type Tube port Female thread Option Thread style NIL Port size Tube size Thread style NI...

Page 10: ...sh water viscosity 1mPa s specific gravity 1 0 Thus if the fluid with higher viscosity such as oil is used convert the fluid to fresh water with reference to viscosity characteristic graph The dischar...

Page 11: ...ge rate of fresh water Since discharge rate 45 of fresh water is equal to 4 5L min of the fluid with the following calculation 4 5L min 0 45 10L min It is found discharge rate 10L min is necessary for...

Page 12: ...ement of pilot air switching part Review of piping at suction or discharge side and removal of restrictor Replacement of pump Supply of air at adequate pressure Cleaning Replacement of pump 2 The pump...

Page 13: ...placement Supply of air at adequate pressure Increase of air supply Removal of back pressure or increase of supplied air pressure 4 A lot of air bubble come out from discharge side FLUID OUT Air is su...

Page 14: ...ntrol valve is shifted and starts reverse operation Fig 2 This repeated operation realizes continuous suction and discharge Air exhaust port AIR EXH Air supply port AIR SUP Discharge port FLUID OUT Su...

Page 15: ...th the round head Philips screws tightening torque 0 125N m Fig 2 3 Insert optical fibers to the amplifier and set the amplifier to Percent tuning At this time the ratio at the threshold level is set...

Page 16: ...r of amp for the sensor 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice...

Reviews: