- 7 -
2-3. Mounting
!
Warning
1. Install and operate the product only after reading the Operation Manual carefully and
understanding its contents. Also, keep the manual where it can be referred to as
necessary.
2. Allow sufficient space for maintenance and inspection.
3. Do not drop or hit the product when mounting to avoid scratches and dents.
Even slight deformation can cause the deterioration of accuracy and operation failure.
4. Tighten the mounting screws of the attachment with the specified torque.
Tightening the screws with a higher torque than the maximum may cause malfunction. In
addition, tightening the screws with a lower torque can cause the displacement of the
mounting position or in extreme conditions, detaching of the work piece.
Mounting attachment to the finger
The attachment should be mounted with the torque specified in the following table by
screwing the bolt into the female mounting thread of the finger.
5. Tighten the screw within the specified torque range when mounting the air gripper.
Tightening with a torque above the limit can cause malfunction, while insufficient
tightening can cause slippage and dropping.
Model No
Screw
Max. tightening
torque (N
・
m)
MHZ2-6
□
MHZJ2-6
□
MHZA2-6
□
MHZAJ2-6
□
M2x0.4
0.15
Attachment