- 12 -
No.JXC#-OMX0009-A
(4) Communication cable for controller setting
To controller PC
JXC
-
W2A
-
C
Communication cable
LEC
-
W2
-
U
USB cable
Operating environment
OS
Window®7,Windows®8.1,Windows®10
Communication interface
USB1.1 or USB2.0 port
Display
1024×768 or more
Windows
Ⓡ
7, Windows
Ⓡ
8.1, and Windows
Ⓡ
10 are registered trademarks of United States Microsoft Corporation.
Caution
The latest version of the controller setting software must be used.
Please download from SMC website. http://www.smcworld.com/
(5) Power supply plug
JXC-CPW
Power Supply Plug
No. Terminal
Function
Details
1
C24V
Control power supply
(+)
Positive control power to be supplied
to the controller.
2
M24V
Motor power (+)
Positive control power to be
supplied to the motor.
3
EMG
Stop (+)
The positive power for Stop signal.
4
0V
Common power (-)
The negative common power for
M24V, C24V, EMG and LK RLS.
5
-
NC
N/A
6
LK RLS
Unlocking (+)
Positive power for unlocking.
Communication cable
USB cable
- Controller Configuration Software
- USB driver
Please download from SMC website.
https://www.smcworld.com