Ionizer (IZS40)
∗
Ground with a ground resistance of 100
W
or less.
A
Make sure to ground the F.G. cable (green) with a ground
resistance of 100
W
or less.
The F.G. cable is used as a reference electric potential for
de-ionization. If the ground terminal is not properly grounded,
an optimal offset voltage cannot be acquired and also causes
failure of the equipment. Be sure to connect the ground
terminal using a ground resistance of 100
W
or less.
1. Grounding of F.G. cable
2. Connection circuit (“POWER” connector)
Wire cables according to the circuitry and wiring chart.
Wiring of the IZS40
e-con is adopted for the connector of the IZS40.
Connector with cable or without cable may be selected
when placing an order for the power supply cable.
When only an e-con is required, place an order for it as
a part. (Cable is not supplied.)
How to connect the cable of the connector
1) Cut the cable as shown in the figure to the below.
Refer to the following table for the applicable wire size.
2) Insert the cable which was cut into the back of the
connector.
3) Confirm that the cable is inserted into the back of the
connector and press part A with your finger to hold
tentatively.
4) Use a tool such as pliers to firmly tighten the center
of part A.
5) The connector cannot be reused once crimped. If
cable insertion fails, use a new connector.
Wiring
Applicable Wire
Wiring: IZS40
Connection Circuit: IZS40
If cables are prepared by the user, the cable colors shown in the diagram may change according to the cable colors by the user.
Number stamped on connector
20 mm or more
F.G.
+24 V
Power
supply
24 VDC
0 V
Internal circuit
1
2
3
4 (Unused)
Shield
Brown
Blue
Green
F.G.
Number stamped on connector Signal name
Description
1
+24 VDC
Connect the power supply to operate the ionizer.
2
0 V
3
F.G.
Make sure to ground with a ground resistance of 100
W
or
less to use it as a reference electric potential for ionizer.
If not grounded, performance cannot be acquired, and
also causes failure of the equipment.
4
—
Unused
AWG
No.
Conductor cross section
[mm
2
]
Finish O.D.
[mm]
Model
26-24
0.14-0.2
ø0.8-ø1.0
ZS-28-C
20
Ionizer
IZS40/41/42
Series