The potential amplitude can be reduced with
SMC’s original dual AC type sensor.
Static neutralization in consideration of damage to a device which is sensitive to electrostatic discharge (ESD) can be achieved.
The potential amplitude generated in the applicable workpiece is reduced even if the workpiece is mounted within close proximity of the ionizer.
Potential amplitude:
25
V or less
80%
reduction compared to the existing model
(Compared to the IZS31 series at an installation height of 300 mm)
Simple operation: Can be controlled by
powering the ionizer ON
Implementation of our original dual AC type
+ ions and − ions are dis-
charged at the same time to
allow the + and − ions to
reach the workpiece evenly,
thereby reducing the potential
amplitude.
AC type
+ ion and − ion layers reach
the workpiece alternately,
which increases the potential
amplitude.
<Conditions> Ion generation frequency: 30 Hz, Supply pressure: 0.1 MPa,
High speed static neutralization cartridge
For the static neutralization of glass substrates
For the static neutralization of electric substrates
Dual AC Type
IZS42
Series
(Potential amplitude reduction specification)
Standard Type IZS40
Series
IZS40/41/42
Series
0
11
10
9
8
7
6
5
4
3
2
1
0
500
1000
1500
2000
Installation distance [mm]
Discharge time [s]
Static neutralization data when the voltage is reduced from 1000 V to 100 V
IZS40
41
%
Prevents the breakage of glass substrates
by the static electricity generated when the
substrate is lifted from the surface plate
Prevents the breakage of electric substrates
by the static electricity generated when the
substrates are picked up after dicing
Ionizer
An e-con connector is used.
Suitable for the static neutralization of resin and rubber
pieces (small parts)
e-con connector
The operating mode after static neutralization (when electrostatic potential: within ±30 V) can be selected.
Energy saving mode
Stops generating ions after static neutralization to reduce power consumption
Continuous static neutralization mode
After static neutralization, the ionizer continues to neutralize
static electricity in AC mode while maintaining the electrostatic potential within
±
30 V.
·Prevents element disruption due to discharge
·Prevents the adhesion of dust
For the static neutralization of PET bottles
·Prevents bottles from falling over on
conveyor belts
·Prevents the adhesion of dust
For the static neutralization of molded goods
·Improves the detachability of molded
goods from the mold
For the static neutralization
of glass substrates
·Prevents breakage due to adhesion and discharge
·Prevents the adhesion of dust
Rapid static neutralization by a feedback sensor
Feedback Sensor Type IZS41
Series
Feedback sensor
Detects the polarity of the object
to be neutralized and measures
the charged voltage
−
+
−
+
Stop
Ion emission waveform
Operating mode
Energy saving mode
Continuous static
neutralization mode
−
+
AC (Without sensor)
Workpiece
electrification
Static neutralization
completion
Time
Charged voltage
Generates ions of the opposite
polarity outside of the
±
30 V range
AC operation
within
±
30 V
3
2
1
0
−1
−2
−3
1
2
3
4
Time [s]
Electrostatic potential [kV]
With sensor
Without sensor
With sensor
Without sensor
Continuous static neutralization mode
Supply pressure: 0.1 MPa, Ion generation frequency: 30 Hz,
High speed static neutralization cartridge (8.6 L/min (ANR)/Cartridge)
Discharge time [s]
10
8
6
4
2
0
500
1000
1500
2000
Installation distance
L [mm]
Installation height of sensor: 25 mm
Ionizer
Workpiece
L
With sensor
Without sensor
∗
An auto balance sensor
is installed.
An AC adapter power
supply is available.
Comparison of potential amplitude between AC type and dual AC type
(Installation height of sensor: 300 mm)
−40
−20
0
20
40
Time
Surface potential of workpiece [V]
AC type
Dual AC type
IZS42
25 V
or less
Sensing A
C
Existing model
(High speed static neutralization specification)
Discharge time =
3.2
seconds
(41% faster)
when installed at a long distance (1000 mm)
For the static neutralization
of electric substrates
The discharge speed can be increased by using a feedback sensor (option) to detect the
workpiece's electrostatic potential and continuously emit ions of the opposite polarity.
Dual AC type IZS42
1