background image

 

- 9 - 

  If  an  incorrect  key  is  pressed  or  incorrect  information  is  displayed  during  setting,  power 

must be turned off and the procedure started again. 

  It  is  recommended  that  the  settings  are  changed  without  supply  pressure.  The  product 

operates immediately maximum and minimum pressures are set and the S-key is pressed. 

  It  is  recommended  that  the  minimum pressure  is  output  when  air  is  supplied  to  the  inlet, 

even if the input signal has not been entered. 

  Output pressure from this product and state of operation are changed by changing of each 

setting  and  function.  Each  setting  and  function  should  be  operated  by  trained  and 
experienced operator. 

 
 
 

Flow of the setting 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Power ON 

Unlock keys 

Lock keys 

Reset 

Setting of min. pressure 

Setting of max. pressure 

Setting of switch output 

Detail Setting Mode 

Gain 

Zero clear 

Initialize 

Refer to P9 

Refer to P10-11 

Refer to P9 

Refer to P12 

Refer to P13-15 

 

 
 

(Note1) Please refer to each section for the operation method. 
(Note2) The function of the setting of switch output refers to the switch output type only. 

 
 
 
 

Key locking function 

 

△△△△

,

  Caution

 

Summary of Contents for ITVX Series

Page 1: ...the product only after reading the Operation Manual carefully and understanding its contents Specifically read the safety instructions carefully Keep this operation manual available whenever necessary...

Page 2: ...ng method P6 Setting method P8 Key locking function P9 Setting of min pressure max pressure and switch output P10 Mode of switch output P11 Reset function P12 Error indicating function P12 Detail sett...

Page 3: ...eferring to its latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring the equipment 2 Only personnel with appropriate training sho...

Page 4: ...rest sales branch 2 For any failure or damage reported within the warranty period which is clearly our responsibility a replacement product or necessary parts will be provided This limited warranty ap...

Page 5: ...Therefore flush the piping thoroughly and mount a suitable filter to prevent foreign matter such as metal powder and dust from entering the product Take safety measures by installing safety devices e...

Page 6: ...upted or shut off since the life of the product may be shortened The optional cable connector is a 4 wire type When the monitor output analogue output or switch output is not being used prevent the un...

Page 7: ...ves relays etc 4 Turn off the power supply before inserting or removing the connector 5 Ground the F G terminal at the front of the main body Please note that the right angled cable connector does not...

Page 8: ...ernative cable is used Current Voltage type ITVX2030 0 ITVX2030 1 ITVX2030 2 ITVX2030 3 Power supply 24 VDC Input signal 4 20mADC ITVX2030 0 0 20mADC ITVX2030 1 0 5VDC ITVX2030 2 0 10VDC ITVX2030 3 Wi...

Page 9: ...cuit will operate Er 5 will be displayed and the operation will stop Please install a load to give an output current of 80 mA or less When a current of approx 150 mA or more is applied the over curren...

Page 10: ...ot been entered Output pressure from this product and state of operation are changed by changing of each setting and function Each setting and function should be operated by trained and experienced op...

Page 11: ...ed for approx 1 second Key lock is released current pressure is displayed Note Press key to cancel Locking the keys No Key operation LED Display current pressure is displayed Press key for 2 seconds o...

Page 12: ...P9 Minimum pressure F_1 adjusting range Maximum pressure F_2 adjusting range 0 90 100 4 0 0 0 12 10 2 5 5 20m A 20m A 5V 10V 0 10 120 4 0 0 0 12 10 2 5 5 20m A 20m A 5V 10V 100 Note1 F_1 is adjustable...

Page 13: ...output type ITVX2030 2 3 P_1 P_2 P_1 P_2 Window comparator mode Hysteresis mode O N O FF P_1 P_2 O N O FF P_1 P_2 P_1 P_2 0 Out of range mode The switch output turns on when set pressure is achieved O...

Page 14: ...the power supply Reading or writing errors occurred in EEPROM Please execute Initialize refer to P15 when the ITVX does not operate normally after reconnecting the power supply Please contact SMC whe...

Page 15: ...adjustment of gain The product can change the response time using this gain setting When the gain is changed to a larger value the response will be faster but there is a possibility that stability wil...

Page 16: ...ved No Key operation LED Display Unlock keys refer to P9 Press S key for 2 seconds or more then go to detail setting mode To F03 by using the and keys displayed alternately Press S key displayed alter...

Page 17: ...than 5 seconds to Turning off for 1 second Returns to the state immediately after turning on the power supply keys are locked LED display The range of the LED pressure display is different according t...

Page 18: ...3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2012 SMC Corporation All Righ...

Reviews: