background image

       

    

Wiring and LED display  

 CAUTION

 

 

Incorrect wiring may lead to breakage. 

 

Select a DC power supply with adequate capacity with low ripple. 

 

Insert/pull out the connector after cutting the power supply. 

 

The right angle cable connector does not rotate. Do not rotate it.

 

 

■  ITV connector pin assignment 

Item 

Pin assignment 

Wire color  

(Note 1) 

1.+24[V] 

Brown 

2.N.C. 

− 

3.GND 

Blue 

Power supply 

connector (Plug) 

 

 

4.N.C. 

− 

1.N.C. 

− 

2.RXD/TXD̲N(A) 

Green 

3.N.C. 

− 

4.RXD/TXD̲P(B) 

Red 

Communication 

connector 

(Socket)(Note 2) 

 

5.N.C. 

− 

 

 

 

Note 1. Wire color when SMC cable is used. 

Note 2.  SMCʼs PCA-1557691 (cable with shield) is recommended as the communication cable. 

The cable shield and the metal part of the connector conduct electricity, and electricity 

is connected to the ground from the body through the substrate. Care should be taken when 

a cable made by other company is used.

 

―5― 

 

                                 

 

RUN  LED

DIA  LED

Switch cover

 

Power supply connector 

(Plug)

 

Communication

 

connector 

BF  LED

■  Connection to external equipment 
 

 

4:NC

3:GND

2:NC

1:+24V 

 

Power Supply 

DC24V 

Power supply  wiring diagram 

Communication wiring  
diagram 

5:NC 

4:RXD/TXD̲P 

3:NC 

2:RXD/TXD̲N 

1:NC 

Master 
PLC 

 
 
 
 
 
 
 

Summary of Contents for ITV1000 series

Page 1: ...Precautions for Handling P3 4 Wiring and LED display P5 6 Mounting and Installation P6 Switch setting P7 Pressure setting P8 System configuration Applications Specifications P9 10 Maintenance and ins...

Page 2: ...ideration to any possibility of equipment failure when configuring the equipment Only personnel with appropriate training should operate machinery and equipment Compressed air can be dangerous if an o...

Page 3: ...If the pressure supply is cut while power is supplied the built in solenoid valve will keep operating and may make a buzzing noise This may affect the life of the solenoid valve Be sure to cut the po...

Page 4: ...nd power transmission lines as far as possible so as not to be affected by noise For inductive loads such as solenoid valves and relays make sure to take measures against load surge Ensure the power s...

Page 5: ...Socket Note 2 N C 4 3 2 3 4 5 2 Note 1 Wire color when SMC cable is used Note 2 SMC s PCA 1557691 cable with shield is recommended as the communication cable The cable shield and the metal part of the...

Page 6: ...nstallation Direct mounting When the product is mounted directly onto the panel or device use screws suitable for the thread holes below See drawing on the right Direct mounting Bracket mounting Serie...

Page 7: ...of ADDRESS setting mode Node address of the product can be set by software mode SW and hardware mode HW When software mode is selected the node address is set by the communication master Setting range...

Page 8: ...location Target value 0 area Set target value Resolution 12bit 100 F S Occupied byte 2 Byte b0 b15 b11 12bit 0 0 0 0 Put 0 in upper 4 bits Note Output pressure I area Monitor the output pressure Resol...

Page 9: ...on Specifications ITV1010 ITV1030 ITV1050 ITV2010 ITV2030 ITV2050 ITV2090 Model ITV3010 ITV3030 ITV3050 Minimum supply pressure Set pressure 0 1MPa Set pressure 13 3kPa Maximum supply pressure 0 2MPa...

Page 10: ...duct Switching by switch Note Baud rate relates to communication distance Maintenance and inspection Turn off the power supply stop the supplied air exhaust the residual compressed air and verify the...

Reviews: