Air Dryer
2 Transportation / Installation
2
-
2
•
Circumstances where too much force
and weight are put on the body of the
equipment that causes it to deform.
•
Circumstances where enough spaces
cannot be taken to do maintenance (in
the plant where the equipment is
operated).
Spaces needed for maintenance
Front
: 600 mm
Rear
: 600 mm
Top
: 600 mm
Right
: 600 mm
Left
: 600 mm
•
Locations the ventilation grille of the
equipment can be blocked.
•
Place where rejection style air of air
compressor or other driers (hot wind) is
inhaled.
Warning
Do not use and store in environment having compressed air or ambinet atmosphere which
includes the following substances. It could result in failure of the product and damage of
components, which leads to injury.
- Corrosive gas, Organic solvent, Chemicals
2 - 2 - 2 Anchorage
•
The air dryer should be installed on a vibration-free, stable, horizontal flat surface.
•
Refer to “Chapter6 6-2 Dimensions” for the dimensions.
•
Fix by bolts to prevent falling down. The bolts can be prepared separately as an accessory.
Model No.
Name
Quantity
Applicable Model
IDF-AB501
Anchor bolt set
1 (4 pcs
/
1 set)
IDU22E,IDU37E,IDU55E,IDU75E
2 - 2 - 3 Air
piping
•
Connection to the inlet and outlet of compressed air should be made removable by using union and so
on.
•
Pressing the hexagonal fitting with screw wrench and so on, connect the air piping fittings to the body.
•
Prevent the weight of the piping or unreasonable pressure that is caused in the process of piping from
loading on the equipment.
•
Be careful not to let the vibration of the air compressor transmit.
•
If the temperature of compressed air on the inlet side is higher than 80
o
C, place an aftercooler after the
air compressor. Or, make the temperature of the place where the air compressor is installed lower than
80
o
C.
•
Flush pipes and fittings before connection to prevent dust or chips from entering the air dryer. Those
dusts or oil entered in the piping cause incomplete refrigeration and failures of the equipment.
•
Use pipes and fittings that have enough endurance against the operating pressure and temperature.
And connect it firmly to prevent air leakage.
•
Provide bypass piping to make it possible to do maintenance without stopping the air compressor.
We recommend the bypass piping sets that
we are selling separately as accessories.
Model No.
Name
Q.t
Applicable
Model
IDU-BP336 1
IDU22E
IDU-BP337 1
IDU37E
1 IDU55E
IDU-BP338
Bypass
piping
sets
1 IDU75E
Compressed Air (OUT)
Compressed Air (IN)
Valve (IN)
Valve (OUT)
Union Joint
Union Joint
Bypass
Valve