8.6.3 Setting mode, Level 3
1.Unit Number
Setting range : 0-F (Hex decimal)
Indicated content : Unit number (Ex. : 0)
Function : Sets unit number used. This item is
applicable only when multiple units are
used.
2. Baud Rate
Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s
Indicated content : Baud rate (Ex. : 1200b/s)
Function : Sets baud rate for communication.
3. Parity Bit
Setting range : Without (no parity), Odd, Even
Indicated content : Parity bit (Ex. : Without)
Function : Sets parity bit for communication.
4. Data Length
Setting range : 7Bits, 8Bits
Indicated content : Data length(Ex. : 8Bits)
Function : Sets data length for communication.
5. Stop Bit
Setting range : 1Bit,2Bits
Indicated content : Stop bit(Ex. : 1Bit)
Function : Sets stop bit for communication.
U n i t N u m b e r
M O D E < 0
B a u d R a t e
M O D E < 1 2 0 0 b / s
P a r i t y B i t
M O D E < W i t h o u t
D a t a L e n g t h
M O D E < 8 B i t s
S t o p B i t
M O D E < 1 B i t