background image

Mounting and Installation

(unit: mm)

Mounting screw

L-type bracket
(Through hole)

L-type bracket
(Tapped)

Manifold mount (using ZS-36-A   )

L-type bracket
(Through hole)

Mounting screw
(M3 x 15L)

L-type bracket
(Tapped)

Thread tightening torque is 0.32

0.02N•m.

Mounting screw

Mount on one side

Mount on direct 

Mounting screw
(M3 x 15L)

L-type bracket
(Tapped)

Mount on both sides

Thread tightening torque is 0.32

0.02N•m.

Depending on fittings, they interfere each other and not possible for mounting

in series by using bracket.

Piping

Circuit

Load

1k

Blue  DC(-)

Brown  DC(+)

Black   OUT (Analog output) 12 to 24VDC

Analog output : 1 to 5V
Output impedance : Approx. 1k

Main Circuit

Flow characteristic chart (Reference)

PFMV5(05/10/30)

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

0%

20%

40%

60%

80%

100%

Maximum 

rated flow

Flow

PFMV5(05/10/30)F   

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

-100%

-50%

0%

50%

100%

Maximum 

rated flow

Flow

Analog output voltage[V]

Analog output voltage[V]

Recommended fitting list

One-Touch fitting
• Male Connector (One-Touch Male Connector)/KQ2H04-M5
• Hexagon Socket head Male Connector/KQ2S04-M5
• Male Elbow/KQ2L04-M5

One-Touch mini fittings
• Male Connector/KJH04-M5
• Hexagon Socket head Male Connector/KJS04-M5
• Male Elbow/KJL04-M5

PFMV5 series recommended fitting list

Miniature fitting
• Barb fittings for nylon tubing/M-5AN-4/M-5AN-6

During installation of the flow sensor to the pipe, hold the body with specified
spanner

Tightening torque to mount the fitting is 1 to 1.5N

.

m

Refer to catalog for details of flow characteristic.