background image

 

QuickServer Start-Up Guide 

Page 31 of 32 

Appendix C.5. Specifications 

        

           

           

         

 

 

FS-QS-2XX0-XXXX 

2

 

Electrical Connections

 

One 3-pin Phoenix connector with:  RS-485/RS-232 (Tx+ / Rx- / gnd) 
One 3-pin Phoenix connector with:   RS-485 (Tx+ / Rx- / gnd) 
One 3-pin Phoenix connector with:   Power port (+ / - / Frame-gnd) 
One Ethernet 10/100 BaseT port 

Power Requirements 

Input Voltage:

 9-30VDC or 24VAC 

Current draw:

  24VAC 0.125A 

Max Power:

 3 Watts 

9-30VDC 0.25A @12VDC 

Approvals 

CE and FCC Class B & C Part 15, UL 60950, WEEE compliant,  
IC Canada, RoHS compliant 

Capacity Options 

FS-QS-20X0: 250 data points 

FS-QS-22X0: 3,000 data points 

FS-QS-23X0: 500 data points 

FS-QS-24X0: 5,000 data points 

Physical Dimensions 

4 x 1.1 x 2.7 in (10.16 x 2.8 x 6.8 cm) 

Weight 

0.4 lbs (0.2 Kg) 

Operating Temperature  

-20°C to 70°C (-4°F to158°F) 

Humidity 

10-95% RH non-condensing 

Figure 19: Specifications 

“This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:  

 

This device may not cause harmful interference 

 

This  device  must  accept  any  interference  received,  including  interference  that  may  cause 
undesired operation. 

NOTE:

 This equipment has been tested and found to comply with the limits for a Class A digital device, 

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with 
the instruction manual, may cause harmful interference to radio communications. Operation of this 
equipment in a residential area is likely to cause harmful interference in which case the user will be 
required to correct the interference at his expense. Modifications not expressly approved by FieldServer 
could void the user's authority to operate 

the equipment under FCC rules.” 

 

                                                      

2

 

Specifications subject to change without notice.

 

Summary of Contents for FieldServer FS-QS-2XX0

Page 1: ...Document Revision 1 H T18627 FieldServer QuickServer Start up Guide FS QS 2XX0 APPLICABILITY EFFECTIVITY Effective for all systems manufactured after November 2019...

Page 2: ...ical support needs related to the FieldServer product MSA Safety 1991 Tarob Court Milpitas CA 95035 Website www sierramonitor com U S Support Information 1 408 964 4443 1 800 727 4377 Email smc suppor...

Page 3: ...6 6 4 Test and Commission the QuickServer 17 Appendix A Useful Features 18 Appendix A 1 SSL TLS for Secure Connection 18 Appendix A 1 1 Configuring FieldServer as a SSL TLS Server 18 Appendix A 1 1 1...

Page 4: ...nce 29 Appendix C 1 QuickServer FS QS 2XX0 XXXX DCC 29 Appendix C 2 QuickServer Part Numbers 29 Appendix C 3 Compliance with UL Regulations 30 Appendix C 4 Dimension Drawing FS QS 2XX0 XXXX 30 Appendi...

Page 5: ...he Gateway 11 Figure 7 Power Connections 11 Figure 8 Ethernet Port Location 12 Figure 9 FS GUI Network Settings 13 Figure 10 FS GUI File Transfer 14 Figure 11 FS GUI Loading Files 15 Figure 12 Retriev...

Page 6: ...available on the USB drive provided in the optional accessory kit or on the Sierra Monitor website Accessory kit optional Part FS 8915 38 QS includes 7 ft Cat 5 cable with RJ45 connectors at both ends...

Page 7: ...2 4 QUICKSERVER SETUP 4 1 Mounting The QuickServer can be mounted using the DIN rail mounting bracket on the back of the unit NOTE For dimension details see Appendix C 4 Figure 1 DIN Rail Bracket Figu...

Page 8: ...ias resistor is 510 ohms which is in line with the BACnet spec It should only be enabled at one point on the bus for example on the field port were there are very weak bias resistors of 100k Since the...

Page 9: ...re 4 Termination resistor is also used to reduce noise It pulls the two lines of an idle bus together However the resistor would override the effect of any bias resistors if connected NOTE The R1 and...

Page 10: ...y Pin Assignment BMS RS 232 Wiring Gateway Pin Assignment RS 485 TX RS 232 TX RS 485 RX RS 232 RX GND GND GND GND NOTE Use standard grounding principles for GND 4 3 2 Supported RS 485 Baud Rates by Pr...

Page 11: ...added to the power supply of the host system A safety margin of 25 is recommended Figure 6 Required Current Draw for the Gateway Apply power to the QuickServer as shown below in Figure 7 Ensure that...

Page 12: ...xxx network For Windows 10 Find the search field in the local computer s taskbar usually to the right of the windows icon and type in Control Panel Click Control Panel click Network and Internet and...

Page 13: ...t to the same IP Address of the router Click Update IP Settings then click on the System Restart to restart the Gateway and activate the new IP Address NOTE If the FS GUI was open in a browser the bro...

Page 14: ...evant device registers in the Config csv file for the initial start up If not the product is shipped with a sample config csv that shows an example of the drivers ordered In the main menu of the FS GU...

Page 15: ...hen File Transfer and finally Update Browse and select the csv file open then click Submit Once download is complete a message bar will appear confirming that the configuration was updated successfull...

Page 16: ...menu of the FS GUI screen click Setup then File Transfer Click the config csv link under the Retrieve heading in the middle section of the screen o The file will automatically download to the web bro...

Page 17: ...the QuickServer Connect the QuickServer to the third party device s and test the application From the landing page of the FS GUI click on View in the navigation tree then Connections to see the numbe...

Page 18: ...Configuration Add TLS_Port parameter in the connections section of the configuration file and set to a port number between 1 65535 Connections Adapter Protocol TLS_Port N1 Modbus TCP 1502 This config...

Page 19: ...er with the following connection settings Connections Adapter Protocol TLS_Port Validate_Client_Cert Cert_Authority_File N1 Modbus TCP 1502 Yes my_authorized_clients pem This configuration has the Fie...

Page 20: ...ymously known as common name host name or domain etc The common name can be obtained by the following methods Ask the certificate issuer for the host name Use online tools to decode the certificate fo...

Page 21: ...rtificate against its own internal authority file before finalizing the connection By default this means the FieldServer will only establish connections to other FieldServers Remote_Node_TLS_Port Vali...

Page 22: ...the PC s Device Manager List and that it is configured to run the TCP IP protocol Check that the IP netmask of the PC matches the QuickServer The Default IP Address of the QuickServer is 192 168 2 X S...

Page 23: ...a snapshot of the loaded configuration files and a log of all the communications over a specified period of time This works for both serial and Ethernet connections NOTE The information in the zipped...

Page 24: ...Start Up Guide Page 24 of 32 Step 1 Take a Log o Click on the diagnose icon of the desired device o Ensure Full Diagnostic is selected this is the default NOTE If desired the default capture period ca...

Page 25: ...d is finished the Diagnostic Test Complete window will appear Step 2 Send Log o Once the diagnostic test is complete a zip file will be saved on the PC o Click Open to launch explorer and have it poin...

Page 26: ...Capture will accelerate diagnosis of the problem Open the FieldServer FS GUI page Click on Diagnostics in the Navigation panel Go to Full Diagnostic and select the capture period Click the Start butto...

Page 27: ...is is the power light and should always be steady green when the unit is powered TX The TX LED will flash when a message is received on the serial port on the 3 pin connector If the serial port is not...

Page 28: ...rt the FieldServer The password needs to be a minimum of eight characters and is case sensitive If the password is lost click cancel on the password authentication popup window and e mail the password...

Page 29: ...ix C 2 QuickServer Part Numbers Field Connections Interface Connections RS 2321 RS 4852 RS 4223 KNX6 RS 485 M Bus Ethernet4 LonWorks5 QuickServer FS QS 2X10 1 2 1 FS QS 2X20 1 2 1 FS QS 1011 1 1 1 FS...

Page 30: ...ng temperature range o Meet the current and voltage rating for QuickServer Net Furthermore the interconnecting power cable shall o Be of length not exceeding 3 05m 118 3 o Be constructed of materials...

Page 31: ...f the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any interference received including interference that may ca...

Page 32: ...or on which original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables or to any damage resulting from battery...

Reviews: