FLEXIBLE ASSEMBLY SYSTEM
FAS200
User Manual for FAS200
- 49 -
Figure 54: Material detection
position.
TECHNICAL DATA
Dimensions:
Table of slotted aluminium section, 450 x 582 mm. Height 900 mm.
Air treatment unit:
Filter to 5 µm, pressure regulator and pressure gauge.
Pushbutton control:
Start, stop, reset pushbuttons. Emergency stop button, main switch on/off,
mode selector (auto-man), no material indicator and error pilot indicator.
Composition of station modules:
Index plate
Actuators:
- Pusher cylinder: Compact double-acting cylinder Ø25, Stroke: 40mm
(CDQ2B25-40D), with flow regulators and initial position detector. Controlled by
5/2 way monostable solenoid valve.
- Locking cylinders: 2 Compact cylinders Ø16, Stroke: 10mm (CQ2B16-10D).
Controlled by 5/2 way monostable solenoid valve.
Sensors:
- Reed type magnetic detector (D-A73CL).
Shaft feeder
Magazine capacity: 17 shafts.
Summary of Contents for FAS-200