EX260-TFN20

Troubleshooting

Contacts

AUSTRIA

(43) 2262 62280 

NETHERLANDS

(31) 20 531 8888 

BELGIUM

(32) 3 355 1464 

NORWAY

(47) 67 12 90 20 

CZECH REP.

(420) 541 424 611 

POLAND

(48) 22 211 9600 

DENMARK

(45) 7025 2900 

PORTUGAL

(351) 21 471 1880

FINLAND

(358) 207 513513 

SLOVAKIA

(421) 2 444 56725 

FRANCE

(33) 1 6476 1000 

SLOVENIA

(386) 73 885 412

GERMANY

(49) 6103 4020 

SPAIN

(34) 945 184 100 

GREECE

(30) 210 271 7265 

SWEDEN

(46) 8 603 1200 

HUNGARY

(36) 23 511 390 

SWITZERLAND

(41) 52 396 3131 

IRELAND

(353) 1 403 9000 

UNITED KINGDOM

(44) 1908 563888 

ITALY

(39) 02 92711

URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)

Specifications are subject to change without prior notice from the manufacturer.
© 2010 SMC Corporation All Rights Reserved.

LED indication

Technical documentation giving detailed troubleshooting information can be
found on the SMC website (URL http://www.smcworld.com)

Setting (Continued)

Terminator

A bus termination is required at both ends of the PROFIBUS DP bus
segment.
<EX260-SPR1/-SPR2/-SPR3/-SPR4>

The bus termination switch is built-in to EX260-SPR1/-SPR2
/-SPR3/-SPR4.
Switch it ON if the SI unit is at the end of the fieldbus segment.

Note: Factory default setting is OFF.

<EX260-SPR5/-SPR6/-SPR7/-SPR8>

EX260-SPR5/-SPR6/-SPR7/-SPR8 do not have a
built-in termination resistor. 
Termination is required on the outside of the SI unit. A termination
switch built-in to the PROFIBUS DP D-sub connector may be used.

ON

OFF

GSD file

Configuration

In order to configure the SI unit in the PROFIBUS DP network, the
appropriate device master file (GSD file) for the SI unit will be required.
The current GSD file can be found on the SMC website
(URL http://www.smcworld.com)

EX260-SPR1/-SPR2

Part number

GSD file

Smc_1430.gsd

EX260-SPR3/-SPR4

Smc_1431.gsd

EX260-SPR5/-SPR6

Smc_1432.gsd

1
2
3

EX260-SPR7/-SPR8

Smc_1433.gsd

4

Output number assignment

The output number refers to the solenoid position on the manifold and
starts at zero.

Bit: 7

0

Bit: 7

0

Bit: 7

0

Bit: 7

0

0

1

2 4 6

3 5 7

8

9

16

17

30

31

28

29

6

4

6

4

1 3 5 7 1

1

5 7

Output No.

Output No.

Bit No.

Bit No.

Valve manifold

Solenoid on side A

Solenoid on side B

Side D

0: Solenoid valve: OFF

1: Solenoid valve: ON

 Byte

 0 Offset
 Byte

 1 Offset
 Byte

 2 Offset
 Byte

 3 Offset

(SI unit side)

2

0

0

0

16 outputs

type

32 outputs

type

Diagnostic information

The EX260 SI unit can support 8 bytes of diagnostic information,
6 bytes standard diagnostic information and 2 bytes SI unit-related
diagnostic information.
Diagnostic information can be requested by the DP master from the SI
unit, and such system fault states can be indicated by the SF LED.
Technical documentation giving detailed diagnostic information can be
found on the SMC website (URL http://www.smcworld.com)

SF

BF

PWR(V)

PWR

PWR(V)

LED

Description

Turns ON in green when load voltage for the valve is supplied
Turns OFF when load voltage for the valve is not supplied or
outside tolerance range (19 V or less)

PWR

Turns ON in green when SI unit operating voltage is supplied

SF

System fault

BF

BUS fault

OFF

BF status

Description

No fault. Communication connection to the
master is established

Red ON

SI unit can not detect a transmission rate and
the connection to the DP master has failed

Red flashing

SI unit has detected the transmission rate,
but is not addressed by the DP master

OFF

SF status

OFF

OFF

OFF

SI unit-related diasgnostic error is detected
(load power for the valve is not supplied or
outside tolerance range)

Red ON

SI unit PROFIBUS DP address outside range

Red flashing

The configuration data sent from the DP
master to the SI unit does not agree with the
SI unit configuration

Red ON

Red ON

Red ON

<Indication of communication status>

Specifications

Connected load: 24 VDC Solenoid valve with light and surge voltage
suppressor of 1.5 W or less (manufactured by SMC)
Current consumption of power supply for SI unit operation: 0.1 A max.
Ambient temperature for operation: -10 to 50 ℃
Ambient temperature for storage: -20 to 60 ℃
Pollution degree 2: (UL508)

Technical documentation giving detailed specifications can be found on the
SMC website (URL http://www.smcworld.com)

Technical documentation giving detailed outline dimensions can be found
on the SMC website (URL http://www.smcworld.com)

Technical documentation giving detailed accessories information can be
found on the SMC website (URL http://www.smcworld.com)

Outline Dimensions

Accessories