D-sub communication connector type

M12 communication connector type

90.9

28.2

102.4

90.9

102.4

28.2

21

20.6

16.4 9

76.5

28.75

29.25

9

76.5

SI Unit Dimensions

Part no.

Communication protocol

EX260-SPR1/-SPR2

        -SPR3/-SPR4

PROFIBUS DP

5 pins, socket, B code

5 pins, plug, B code

5 pins, plug, A code

Note) The setting switch varies depending on the model.
 

Refer to the operation manual for details.

 

Please download it via the SMC website, http://www.smcworld.com

EX260-SDN

DeviceNet™

5 pins, socket, A code

5 pins, plug, A code

4 pins, plug, A code

EX260-SMJ

CC-Link

EX260-SEC

EX260-SPN

EX260-SEN

EX260-SPL

EtherCAT

PROFINET

EtherNet/IP™

POWERLINK

M3

Communication connector (M12) BUS OUT

Communication connector (M12) BUS IN

Ground terminal
Power connector (M12) 

<Setting switch>

• Address switch
• Communication speed switch
• Terminating resistor switch
• Others

<LED indication>

• Communication state
• Unit power supply state
• Valve power supply state

Part no.

Communication protocol

EX260-SPR5/-SPR6/-SPR7/-SPR8

PROFIBUS DP

M3

9 pins, socket

5 pins, plug, A code

Ground terminal
Communication connector (D-sub) BUS IN/OUT
Power connector (M12) 

D-sub communication connector type

Functions of SI Unit Parts

<Connector>
M12 communication connector type

<LED indication and setting switch>

5 pins, socket, A code

Note1)

4 pins, plug, A code

5 pins, plug, B code

4 pins, socket, D code

4 pins, socket, D code

5 pins

Note2)

, 4 pins

Note3)

,

 plug, A code

EX260 

Series

Note 1) Recommended mating M12 

4-pin plug, part no. 
PCA-1567717.

Note 2) For EtherCAT, PROFINET, 

POWERLINK

Note 3) For EtherNet/IP™

794

A

Summary of Contents for EX260-SDN1/3

Page 1: ...EX260 Series Fieldbus System Output device for driving 5 port solenoid valves Daisy chain wiring communication Space saving Installation Space saving Installation Compact 28mm IP67 For units with D s...

Page 2: ...tallation in locations where space is limited above the valve Current model EX250 External branch connector is not necessary Daisy chain wiring is possible Reduced wiring space Branch connector Curren...

Page 3: ...00 7000 Series Pressure switch Piping is possible from 3 directions Mixed mounting of top ported and side ported is possible By mounting top ported valves on side ported and bottom ported type manifol...

Page 4: ...mmon Source PNP Negative common Sink NPN Positive common Source PNP Negative common QAN QA QBN QB NAN NA NBN NB NCN NC NDN ND VAN VA VBN VB DAN DA DBN DB FAN FA FBN FB EAN EA EBN EB GAN GBN Communicat...

Page 5: ...260 SEC1 3 EX260 SEC2 4 EX260 SPN1 3 EX260 SPN2 4 EX260 SEN1 3 EX260 SEN2 4 Applicable system I O occupation area Inputs Outputs Communication speed Power supply for control Powersupplyforoutput Commu...

Page 6: ...OUT Communication connector M12 BUS IN Ground terminal Power connector M12 Setting switch Address switch Communication speed switch Terminating resistor switch Others LED indication Communication stat...

Page 7: ...le with EtherCAT PROFINET EtherNet IP POWERLINK PCA 1446553 5000 mm 1446566 Cable length Fieldwireable connector 6 5 50 5000 47 3 14 8 Plug connector pin arrangement D code 1 2 3 4 M12 SPEEDCON 17 5 1...

Page 8: ...401804 1401805 1401806 1401804 4 3 2 1 14 8 M12 SPEEDCON 44 5 L 50 5 0 5 Socket connector pin arrangement A code Note 1 For DeviceNet Note 2 For EtherNet IP 1 2 3 4 5 Terminal no Core wire colors Conn...

Page 9: ...0 5 6 4 Connections 1 2 3 4 5 Terminal no Cable core wire colors 4 3 2 1 M12 SPEEDCON 14 8 50 L 44 5 5 0 5 Socket connector pin arrangement B code Brown 24 VDC 10 5 Solenoid valve power supply White 0...

Page 10: ...ated from each other 6 Check the wiring insulation Defective insulation contact with other circuits improper insulation between terminals etc may cause damage to the reduced wiring system or output de...

Page 11: ...ormal temperature changes the internal unit is likely to be adversely effec ted 10 Do not use in direct sunlight Do not use in direct sunlight It may cause malfunction or damage 11 Use this product wi...

Page 12: ...otocol is designed by the manufacturer of the PLC used 4 For the EX260 SPN the side of the SI unit may become hot It may cause burns 1 When handling and replacing the unit Do not apply excessive force...

Page 13: ...wire capacitance 3 nF or less 20 m or less IO Link Compatible SI Unit EX260 SIL1 X207 X210 IO Link communication enables users to check unit information and monitor unit status in addition to ON OFF...

Page 14: ...dual voltage 0 4 VDC or less Control unit power supply 18 to 30 VDC 0 1 A or less Weight 200 g or less Standards CE marking UL CSA Suffix Communication connector Power supply connector for solenoid va...

Page 15: ...lenoid output 31 Description Designation No Description Designation No How to Order EX260 X207 Communication protocol IL IO Link IO Link port class X207 IO Link port Class A Valve power supplied from...

Reviews: