background image

SY3000

SY5000

SY7000

S0700

SV1000

SV2000

SV3000

VQC1000

VQC2000

VQC4000

VQC5000

0.19

0.17

0.20

0.39

0.35

0.18

0.21

0.30

0.30

0.38

0.31

  1.6  

  3.6  

  5.9  

  0.37

  1.1  

  2.4  

  4.3  

  1.0  

  3.2  

  7.3  

17     

Series

Power

consumption

(W)

Enclosure

Standards

Flow rate characteristics (4/2

5/3)

C [dm

3

/(s·bar)]

b

Maximum

number of

solenoids

Applicable Valve Series

Note) For units with D-sub communication connector, it is IP40.

32

32

32

24

0.35 (standard)

0.1 (with power- 

saving circuit)

[Starting 0.4,

Holding 0.1]

0.6

0.95 (standard)

0.4 (Low wattage type)

0.4 (standard)

0.35

®

IP67

IP40

IP67

IP67

Side ported

Side ported

Bottom ported

Top ported

<Example of Use>

Valve piping direction variations

SY3000/5000/7000 

Series

Pressure switch

Piping is possible from 3 directions.

Mixed mounting of top ported and side ported is possible.

By  mounting  top  ported  valves  on  side 
ported and bottom ported type manifolds, 
it  is  possible  to  detect  the  output  of  the 
A/B port with a pressure switch.

Valves can be freely connected up to 

24

 stations.

Mixed valve sizes manifold

Valves with different sizes, 
SY3000 and SY5000 or SY5000 
and SY7000, can be mounted 
on the same 
manifold.

It  is  possible  to  connect  only 
the number of valves required, 
from  1  to  24  stations,  to  suit 
the application.
(Maximum number of 
solenoids connected: 32)

mm width valves 

can be connected.

It is possible to connect only the number of 7 mm

   width valves required, from 1 to 24 stations. 
   (Maximum number of solenoids connected: 32)

S0700 

Series

791

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510

PCA

EX

EX260

Summary of Contents for EX260-SDN1/3

Page 1: ...EX260 Series Fieldbus System Output device for driving 5 port solenoid valves Daisy chain wiring communication Space saving Installation Space saving Installation Compact 28mm IP67 For units with D s...

Page 2: ...tallation in locations where space is limited above the valve Current model EX250 External branch connector is not necessary Daisy chain wiring is possible Reduced wiring space Branch connector Curren...

Page 3: ...00 7000 Series Pressure switch Piping is possible from 3 directions Mixed mounting of top ported and side ported is possible By mounting top ported valves on side ported and bottom ported type manifol...

Page 4: ...mmon Source PNP Negative common Sink NPN Positive common Source PNP Negative common QAN QA QBN QB NAN NA NBN NB NCN NC NDN ND VAN VA VBN VB DAN DA DBN DB FAN FA FBN FB EAN EA EBN EB GAN GBN Communicat...

Page 5: ...260 SEC1 3 EX260 SEC2 4 EX260 SPN1 3 EX260 SPN2 4 EX260 SEN1 3 EX260 SEN2 4 Applicable system I O occupation area Inputs Outputs Communication speed Power supply for control Powersupplyforoutput Commu...

Page 6: ...OUT Communication connector M12 BUS IN Ground terminal Power connector M12 Setting switch Address switch Communication speed switch Terminating resistor switch Others LED indication Communication stat...

Page 7: ...le with EtherCAT PROFINET EtherNet IP POWERLINK PCA 1446553 5000 mm 1446566 Cable length Fieldwireable connector 6 5 50 5000 47 3 14 8 Plug connector pin arrangement D code 1 2 3 4 M12 SPEEDCON 17 5 1...

Page 8: ...401804 1401805 1401806 1401804 4 3 2 1 14 8 M12 SPEEDCON 44 5 L 50 5 0 5 Socket connector pin arrangement A code Note 1 For DeviceNet Note 2 For EtherNet IP 1 2 3 4 5 Terminal no Core wire colors Conn...

Page 9: ...0 5 6 4 Connections 1 2 3 4 5 Terminal no Cable core wire colors 4 3 2 1 M12 SPEEDCON 14 8 50 L 44 5 5 0 5 Socket connector pin arrangement B code Brown 24 VDC 10 5 Solenoid valve power supply White 0...

Page 10: ...ated from each other 6 Check the wiring insulation Defective insulation contact with other circuits improper insulation between terminals etc may cause damage to the reduced wiring system or output de...

Page 11: ...ormal temperature changes the internal unit is likely to be adversely effec ted 10 Do not use in direct sunlight Do not use in direct sunlight It may cause malfunction or damage 11 Use this product wi...

Page 12: ...otocol is designed by the manufacturer of the PLC used 4 For the EX260 SPN the side of the SI unit may become hot It may cause burns 1 When handling and replacing the unit Do not apply excessive force...

Page 13: ...wire capacitance 3 nF or less 20 m or less IO Link Compatible SI Unit EX260 SIL1 X207 X210 IO Link communication enables users to check unit information and monitor unit status in addition to ON OFF...

Page 14: ...dual voltage 0 4 VDC or less Control unit power supply 18 to 30 VDC 0 1 A or less Weight 200 g or less Standards CE marking UL CSA Suffix Communication connector Power supply connector for solenoid va...

Page 15: ...lenoid output 31 Description Designation No Description Designation No How to Order EX260 X207 Communication protocol IL IO Link IO Link port class X207 IO Link port Class A Valve power supplied from...