background image

®

RoHS

IP67

IP67

IP67

IP40

Top ported valve

Bottom ported valve

Side ported valve

Mixed valve sizes manifold

7 mm width valve

Applicable Fieldbus protocols

EX260 

Series

Fieldbus System

(Output device for driving 5 port solenoid valves)

Daisy-chain wiring

communication

Space-saving Installation

Space-saving Installation

Compact

28

mm

 IP67

 For units with D-sub connector, and when connected to S0700 manifolds, it is IP40.

 Drives up to 32 solenoids

789

EX12

EX140

EX180

EX260

EX250

EX600

EX500

EX510

PCA

EX

EX260

A

Summary of Contents for EX260-SDN1/3

Page 1: ...EX260 Series Fieldbus System Output device for driving 5 port solenoid valves Daisy chain wiring communication Space saving Installation Space saving Installation Compact 28mm IP67 For units with D s...

Page 2: ...tallation in locations where space is limited above the valve Current model EX250 External branch connector is not necessary Daisy chain wiring is possible Reduced wiring space Branch connector Curren...

Page 3: ...00 7000 Series Pressure switch Piping is possible from 3 directions Mixed mounting of top ported and side ported is possible By mounting top ported valves on side ported and bottom ported type manifol...

Page 4: ...mmon Source PNP Negative common Sink NPN Positive common Source PNP Negative common QAN QA QBN QB NAN NA NBN NB NCN NC NDN ND VAN VA VBN VB DAN DA DBN DB FAN FA FBN FB EAN EA EBN EB GAN GBN Communicat...

Page 5: ...260 SEC1 3 EX260 SEC2 4 EX260 SPN1 3 EX260 SPN2 4 EX260 SEN1 3 EX260 SEN2 4 Applicable system I O occupation area Inputs Outputs Communication speed Power supply for control Powersupplyforoutput Commu...

Page 6: ...OUT Communication connector M12 BUS IN Ground terminal Power connector M12 Setting switch Address switch Communication speed switch Terminating resistor switch Others LED indication Communication stat...

Page 7: ...le with EtherCAT PROFINET EtherNet IP POWERLINK PCA 1446553 5000 mm 1446566 Cable length Fieldwireable connector 6 5 50 5000 47 3 14 8 Plug connector pin arrangement D code 1 2 3 4 M12 SPEEDCON 17 5 1...

Page 8: ...401804 1401805 1401806 1401804 4 3 2 1 14 8 M12 SPEEDCON 44 5 L 50 5 0 5 Socket connector pin arrangement A code Note 1 For DeviceNet Note 2 For EtherNet IP 1 2 3 4 5 Terminal no Core wire colors Conn...

Page 9: ...0 5 6 4 Connections 1 2 3 4 5 Terminal no Cable core wire colors 4 3 2 1 M12 SPEEDCON 14 8 50 L 44 5 5 0 5 Socket connector pin arrangement B code Brown 24 VDC 10 5 Solenoid valve power supply White 0...

Page 10: ...ated from each other 6 Check the wiring insulation Defective insulation contact with other circuits improper insulation between terminals etc may cause damage to the reduced wiring system or output de...

Page 11: ...ormal temperature changes the internal unit is likely to be adversely effec ted 10 Do not use in direct sunlight Do not use in direct sunlight It may cause malfunction or damage 11 Use this product wi...

Page 12: ...otocol is designed by the manufacturer of the PLC used 4 For the EX260 SPN the side of the SI unit may become hot It may cause burns 1 When handling and replacing the unit Do not apply excessive force...

Page 13: ...wire capacitance 3 nF or less 20 m or less IO Link Compatible SI Unit EX260 SIL1 X207 X210 IO Link communication enables users to check unit information and monitor unit status in addition to ON OFF...

Page 14: ...dual voltage 0 4 VDC or less Control unit power supply 18 to 30 VDC 0 1 A or less Weight 200 g or less Standards CE marking UL CSA Suffix Communication connector Power supply connector for solenoid va...

Page 15: ...lenoid output 31 Description Designation No Description Designation No How to Order EX260 X207 Communication protocol IL IO Link IO Link port class X207 IO Link port Class A Valve power supplied from...