Numerical values other than “Moving force,” “Area 1,” and “Area 2” can be used to perform operation under numerical instructions from JXCL
.
Specifi cations
Model
JXCE1
JXC91
JXCP1
JXCD1
JXCL1
JXCLF
JXCM1
Network
EtherCAT
EtherNet/IP™
PROFINET
DeviceNet
®
IO-Link
CC-Link
Compatible motor
Step motor (Servo/24 VDC)
Power supply
Power voltage: 24 VDC
±
10%
Current consumption (Controller)
200 mA or less
130 mA or less
200 mA or less
100 mA or less
100 mA or less
100 mA or less
Compatible encoder
Incremental/Battery-less absolute
Communication specifi
cations
Applicable
system
Protocol
EtherCAT
∗
2
EtherNet/IP™
∗
2
PROFINET
∗
2
DeviceNet
®
IO-Link
CC-Link
Version
∗
1
Conformance Test
Record V.1.2.6
Volume 1 (Edition 3.14)
Volume 2 (Edition 1.15)
Specifi cation
Version 2.32
Volume 1 (Edition 3.14)
Volume 3 (Edition 1.13)
Version 1.1
Port Class A
Ver. 1.10
Communication
speed
100 Mbps
∗
2
10/100 Mbps
∗
2
(Automatic
negotiation)
100 Mbps
∗
2
125/250/500 kbps
230.4 kbps
(COM3)
156 kbps, 625 kbps,
2.5 Mbps, 5 Mbps,
10 Mbps
Confi guration fi le
∗
3
ESI fi le
EDS fi le
GSDML fi le
EDS fi le
IODD fi le
CSP+ fi le
I/O occupation area
Input 20 bytes
Output 36 bytes
Input 36 bytes
Output 36 bytes
Input 36 bytes
Output 36 bytes
Input 4, 10, 20 bytes
Output 4, 12, 20, 36 bytes
Input 14 bytes
Output 22 bytes
1 station, 2 stations,
4 stations
Terminating resistor
Not included
Memory
EEPROM
LED indicator
PWR, RUN, ALM, ERR PWR, ALM, MS, NS PWR, ALM, SF, BF PWR, ALM, MS, NS
PWR, ALM, COM
PWR, ALM, L ERR, L RUN
Cable length [m]
Actuator cable: 20 or less
Cooling system
Natural air cooling
Operating temperature range [
°
C]
0 to 55 (No freezing)
∗
4
Operating humidity range [%RH]
90 or less (No condensation)
Insulation resistance [M
Ω
]
Between all external terminals and the case: 50 (500 VDC)
Safety function
—
—
STO, SS1-t
—
Safety standards
—
—
EN 61508 SIL 3
∗
5
EN 62061 SIL CL 3
∗
5
EN ISO 13849-1 Cat. 3 PL e
∗
5
—
Weight [g]
Screw mounting
220
210
220
210
190
220
170
DIN rail mounting
240
230
240
230
210
240
190
∗
1 Please note that versions are subject to change.
∗
2 Use a shielded communication cable with CAT5 or higher for the PROFINET, EtherNet/IP™, and EtherCAT.
∗
3 The fi les can be downloaded from the SMC website.
∗
4 The operating temperature range for both controller version 1 products and controller version 2 products is 0 to 4 0
°
C. Refer to the
Web Catalogue
for
details on identifying controller version symbols.
∗
5 The above safety integrity level is the max. value. The achievable level varies depending on the confi guration and inspection method of the component.
Be sure to refer to “Safety Manual: JXC#-OMY0009” for more information.
Trademark
EtherNet/IP
®
is a registered trademark of ODVA, Inc.
DeviceNet
®
is a registered trademark of ODVA, Inc.
EtherCAT
®
is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
Example of Operation Command
In addition to the step data input of 64 points maximum in each communication protocol, the changing of each parameter can be performed in real time via numerical data defi ned operation.
<Application example> Movement between 2 points
No.
Movement mode
Speed
Position
Acceleration Deceleration Pushing force Trigger LV Pushing speed Moving force
Area 1
Area 2
In position
0
1: Absolute
100
10
3000
3000
0
0
0
100
0
0
0.50
1
1: Absolute
100
100
3000
3000
0
0
0
100
0
0
0.50
<Step no. defi ned operation>
Sequence 1: Servo ON instruction
Sequence 2: Instruction to return to origin
Sequence 3: Specify step data No. 0 to input the DRIVE signal.
Sequence 4: Specify step data No. 1 after the DRIVE signal has been
temporarily turned OFF to input the DRIVE signal.
<Numerical data defi ned operation>
Sequence 1: Servo ON instruction
Sequence 2: Instruction to return to origin
Sequence 3: Specify step data No. 0 and turn ON the input instruction fl ag (position).
Input 10 in the target position. Subsequently the start fl ag turns ON.
Sequence 4: Turn ON step data No. 0 and the input instruction fl ag (position)
to change the target position to 100 while the start fl ag is ON.
The same operation can be performed with any operation command.
0
10 100
Sequence 1
J
Sequence 2
J
Sequence 3
J
Sequence 4
J
19
JXCE1/91/P1/D1/L
/M1
Series