background image

DXT1215-TF222-009EN 

Page 1 of 2 

 

 

Instruction Manual 

High Speed Pilot Operated 5 Port Solenoid 
Valve  

Series DXT1215 

 
 
 
 
 
 
 
 
The intended use of this valve is to control the movement of an actuator.

 

1 Safety Instructions 

These  safety  instructions  are  intended  to  prevent  hazardous  situations 
and/or  equipment  damage.  These  instructions  indicate  the  level  of 
potential hazard with the labels of “Caution,” “Warning” or “Danger.” 
They are all important notes for safety and must be followed in addition 
to International  Standards (ISO/IEC)

 *1)

, and other safety regulations. 

*1)

 ISO 4414: Pneumatic fluid power - General rules relating to systems.  

ISO 4413: Hydraulic fluid power - General rules relating to systems. 
IEC 60204-1: Safety of machinery - Electrical equipment of machines.        
(Part 1: General requirements) 
ISO  10218-1:  Robots  and  robotic  devices  -  Safety  requirements  for 
industrial robots - Part 1: Robots. 

  Refer  to  product  catalogue,  Operation  Manual  and  Handling 

Precautions for SMC Products for additional information. 

  Keep this manual in a safe place for future reference. 

 

 

Caution 

Caution indicates a hazard with a low level of risk which, if 
not avoided, could result in minor or moderate injury. 

 

Warning 

Warning indicates a hazard with a medium level of risk 
which, if not avoided, could result in death or serious injury. 

 

Danger 

Danger indicates a hazard with a high level of risk which, if 
not avoided, will result in death or serious injury. 

 Warning 

 

Always  ensure  compliance  with  relevant  safety  laws  and 
standards. 

  All work must be carried out in a safe manner by a qualified person in 

compliance with applicable national regulations. 

 Caution 

  The  product  is  provided  for  use  in  manufacturing  industries  only. Do 

not use in residential premises. 

2 Specifications 

2.1  Valve specifications 

Valve type 

Rubber seal 

Fluid 

Air 

Internal pilot operating 

pressure range [MPa]

 

 

2 position 
single 

0.3 to 0.6 

Ambient and fluid temperature [

C]

 Note 1)

 

-10 to 60 (No freezing) 

Minimum operating frequency  

1 cycle / 30 days 

Maximum operating frequency [Hz] 

200 

Duty cycle 

Continuous  

(1.5W standard power saving type) 

Flow rate 

Refer to catalogue 

Response time 
Manual override 

Non-locking push type 

Pilot exhaust type 

Internal pilot 

Common exhaust for main & pilot valve 

Lubrication 

Not required 

Mounting orientation 

Unrestricted 

Impact/vibration resistance

 Note 2)

 

150 / 30 

Enclosure (based on IEC60529) 

IP67 

Weight 

Refer to catalogue 

Table 1. 

2 Specifications - continued 

Note 1)  The upper limits of the ambient and fluid temperatures vary depending on 

the  operating  frequency.  (Refer  to  figure1.)  If  a  follow-up  operation  is 
performed  at  a  duty  ratio  of  50%  or  higher,  the  upper  limit  value  may 
change. Please contact SMC for further details. 

Note 2)  Impact resistance

:

 No malfunction occurred when it was tested with a drop 

tester in the axial direction and at right angles to the main valve & armature; 
in  both  energized  &  de-energised  states  and  for  every  time  in  each 
condition. (Values quoted are for a new valve). 
Vibration resistance

:

 No malfunction occurred in a one-sweep test between 

45 and 2000 Hz. Tests are performed at both energized and de-energized 
states in the axial direction and at right angles to the main valve & armature. 
(Values quoted are for a new valve). 

 

 

Figure 1. The upper limit of ambient and fluid temperature 

2.2  Solenoid specifications 

Coil rated voltage [VDC] 

24 

Electrical entry 

M8 connector 

Allowable voltage fluctuation [V]

 Note 1)

 

-5 to 10% of rated voltage 

Power consumption [W] 

Note 2, 3)

 

With power  
saving circuit 

1.5 

(Inrush 6, Holding 1.5) 

Surge voltage suppressor 

Diode 

Indicator light 

LED 

Table 2. 

Note 1)  Valve state is not defined if electrical input is outside of specified operating 

ranges. 

Note 2)  DXT1215 series available as power saving type only.  
Note 3)  Refer to section 3.8 for details.  

2.3  Indicator light 

This valve has an indicator light and surge voltage suppressor. The light 
turns red when the solenoid is energized. 

 

Figure 2. Light indication 

2.4  Special products 

 Warning 

Special  products  (-X)  might  have  specifications  different  from  those 
shown in this section. Contact SMC for specific drawings. 

3 Installation 

3.1  Installation 

 Warning 

  Do not install the product unless the safety instructions have been read 

and understood. 

3.2  Environment 

 Warning 

  Do not use in an environment where corrosive gases, chemicals, salt 

water or steam are present. 

  Do not use in an explosive atmosphere. 

  Do not expose to direct sunlight. Use a suitable protective cover. 

  Do not install in a location subject to vibration or impact in excess of 

the product’s specifications.  

  Do not mount in a location exposed to radiant heat that would result in 

temperatures in excess of the product’s specifications. 

Installation - continued 

  Products  with  compliant  with  IP67  enclosures  are  protected  against 

dust and water; however, these products cannot be used in water. 

  Products compliant to IP67 satisfy the specifications by mounting the 

product  appropriately.  Be  sure  to  read  the  Specific  Product 
Precautions for each product. 

  Do  not  use  in  high  humidity  environment  where  condensation  can 

occur. 

  If using in an atmosphere where there is possible contact with water 

drop-lets, oil, weld spatter, etc., take suitable preventive measures. 

  Contact SMC for altitude limitations. 

3.3  Piping 

 Caution 

  Before connecting piping make sure to clean up chips, cutting oil, dust 

etc. 

  When  installing  piping  or  fittings,  ensure  sealant  material  does  not 

enter inside the port. When using seal tape, leave  1 thread

 

exposed 

on the end of the pipe/fitting.  

  For  internal  pilot  valves,  even  though  the  inlet  pressure  is  within the 

operating pressure range, when the pipe diameter is restricted due to 
size reduction of supply port 1(P), the flow will be insufficient. In this 
case,  the  valve  does  not  switch  completely,  and  the  cylinder  may 
malfunction. 

  Tighten fittings to the specified tightening torque. 

Connection thread size (R, NPT)  

Tightening torque [N∙m] 

1/8 

3 to 5 

Table 3. 

3.4  Lubrication 

 Caution 

  SMC products have been lubricated for life at manufacture, and do not 

require lubrication in service. 

  If a lubricant is used in the system, refer to catalogue for details. 

3.5  Air supply 

 Warning 

  Use  clean  air.  If  the  compressed  air  supply  includes  chemicals, 

synthetic materials (including organic solvents), salinity, corrosive gas 
etc., it can lead to damage or malfunction. 

 Caution 

  Install  an  air  filter  upstream  of  the  valve.  Select  an  air  filter  with  a 

filtration size of 5μm or smaller. 

3.6  Manual override 

 Warning 

  Regardless of an electric signal for the valve, the manual override is 

used  for  switching  the  main  valve.  Since  connected  equipment  will 
operate when the manual override is activated, confirm that conditions 
are safe prior to activation. 

  Refer to the catalogue for details of manual override operation. 

 

Figure 3. 

3.7  One-touch fittings 

3.7.1 Tube attachment and detachment 

 Caution 

Refer to the Specific Precautions in the catalogue. 

3.7.2 Precautions on other tube brands 

 Caution 

When  using  non-SMC  brand  tubes,  refer  to  the  Specific  Product 
Precautions in the fittings and tubing catalogue. 

3.8  Electrical circuits 

3.8.1 With power saving circuit (non-polar type) 

  Power consumption is decreased by approximately 1/4 of the amount 

required at start up by reducing the wattage required to hold the valve 
in an energized state. 
(Effective energizing time is over 5 ms at 24 VDC). 

Installation - continued 

 

Figure 4. With power saving circuit. 

  The above circuit reduces the power consumption for holding in order 

to save energy.  

  Refer to the catalogue for additional information. 

3.9  Wiring 

 Caution

 

  Do not use a tool to mount the connector as this may cause damage. 

Tighten the connector by hand (torque of 0.4 N∙m to 0.6 N∙m). 

  Applying  excessive  force  on  the  cable  connector  will  result  in  it  no 

longer being able to satisfy IP67 requirements. Please use caution and 
refrain from applying 30 N or more force on the connector. 

  Refer to catalogue for additional information.  

 

Figure 5. Solenoid valve side pin wiring diagram 

Note: There is no grounding for this product. 

 

Figure 6. Connector cable 

3.10 Residual voltage 

Caution 

  The suppressor arrests the back EMF voltage from the coil to a level 

in proportion to the rated voltage.  

  Ensure  the  transient  voltage  is  within  the  specification  of  the  host 

controller.   

  In the case of a diode, the residual voltage is approximately 1 V. 

3.11 Countermeasure for surge voltage 

Caution

 

 

  At times of sudden interruption of the power supply, the energy stored 

in a large inductive device may cause non-polar type valves in a de-
energised state to switch.  

  When installing a breaker circuit to isolate the power, consider to install 

a surge absorption diode across the output of the breaker.  

3.12 Extended period of continuous energization 

Caution 

If a valve will be continuously energized for an extended period of time or 
is mounted in a control panel, the temperature of the valve will increase 
due to the heat generated by the coil assembly. This will likely adversely 
affect the performance of the valve and any nearby peripheral equipment.  

3.13 One-touch fittings 

 Caution 

When fittings are used, they may interfere with one another depending 
on their types and sizes. Therefore, the dimensions of the fittings to be 
used should first be confirmed in their respective catalogues. 

4 How to Order 

Refer  to catalogue

 

for ‘How to Order’ or to product drawing for special 

products. 

5 Outline Dimensions  

Refer to

 

catalogue

 

for outline dimensions. 

ORIGINAL INSTRUCTIONS 

 

 

 

 

Operating frequency [Hz] 

Ambient and flui

te

m

p

e

ra

tu

re

 

(uppe

r limit) [°

C]

 

Solenoid  

Light: red  

Manual override 

Coil 

Di

od

e

 

En

er

gy 

sa

vin

IC

 

LED 

Blue: 3 

Brown: 1 

Sheath 

Covering 

Black: 4 

 