6 Maintenance 

6.1  General maintenance 

 Caution 

  Not following proper maintenance procedures could cause the product 

to malfunction and lead to equipment damage. 

  If handled improperly, compressed air can be dangerous. 

  Maintenance  of  pneumatic  systems  should  be  performed  only  by 

qualified personnel. 

  Before performing maintenance, turn off the power supply and be sure 

to  cut  off  the  supply  pressure.  Confirm  that  the  air  is  released  to 
atmosphere. 

  After  installation  and  maintenance,  apply  operating  pressure  and 

power  to  the  equipment  and  perform  appropriate  functional  and 
leakage tests to make sure the equipment is installed correctly. 

  If any electrical connections are disturbed during maintenance, ensure 

they  are  reconnected  correctly  and  safety  checks  are  carried  out  as 
required  to  ensure  continued  compliance  with  applicable  national 
regulations. 

  Do not make any modification to the product. 

  Do  not  disassemble  the  product,  unless  required  by  installation  or 

maintenance instructions. 

  When the equipment is operated after remounting or replacement, first 

confirm  that  measures  are  in  place  to  prevent  lurching  of  actuators, 
etc. Then, confirm that the equipment is operating normally. 

  Operate the valve at least once every 30 days. 

7 Limitations of Use 

7.1  Limited warranty and disclaimer/compliance requirements 

Refer to Handling Precautions for SMC Products. 

 Warning 

7.2  Effect of energy loss on valve switching 

The use of 2-position single valves with air returned or air/spring returned 
spools has to be carefully considered. 

Energy source status 

Single solenoid 

Air supply present, electrical 
supply cut 

Spool returns to the off position by air and 

spring force 

Electrical supply present, air 
supply cut 

Spool stops moving after air pressure cut 

(Position cannot be defined) 

Table 4. 

Note) 

Applies  to  when  the  spool  is  at  the  end  position  and  at  an  intermediate 
position. 

7.3  Holding of pressure 

Since  valves  are  subject  to  air  leakage,  they  cannot  be  used  for 
applications such as holding pressure (including vacuum) in a system. 

7.4  Cannot be used as an emergency shut-off valve 

This  product  is  not  designed  for  safety  applications  such  as  an 
emergency shut-off valve. If the valves are used in this type of system, 
other reliable safety assurance measures should be adopted. 

7.5  Safety relays or PLC 

If a safe output from a safety relay or PLC is used to operate this valve, 
please contact SMC. 

 Caution

 

7.6  Leakage voltage 

Ensure that any leakage voltage caused by the leakage current when the 
switching element is OFF causes ≤ 3% of the rated voltage across the 
valve. 

 

7.7  Low temperature operation 

Unless otherwise indicated in the specifications for each valve, operation 
is possible to -

10˚C, but appropriate measures should be taken to avoid 

solidification or freezing of drainage and moisture, etc.  

7.8  3 port specification (DXT1215T-5

U-01

-X1) 

  The  3-port  specification  is  a  specification  with  the  2(B)  port  plugged 

and closed. The 3(EB) port should be kept open for pilot exhaust.  

  When one of the cylinder ports 4(A) or 2(B) is closed with a plug and 

used as a 3-port valve, the surface temperature of the plug may rise 
due to adiabatic compression. Therefore, we recommend the use of a 
screw-in metal plug instead of a plastic plug with one-touch fittings. 

 

Figure 7. 

8 Product Disposal 

This  product  shall  not  be  disposed  of  as  municipal  waste.  Check  your 
local regulations and guidelines to dispose this product correctly, in order 
to reduce the impact on human health and the environment. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

9 Contacts 

Refer  to  www.smcworld.com  or  www.smc.eu  for  your  local 
distributor/importer. 

 

 

URL :  

https:// www.smcworld.com (Global)      https:// www.smc.eu (Europe) 

SMC Corporation, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, Japan 
Specifications are subject to change without prior notice from the manufacturer.  
© 2022

 

SMC Corporation All Rights Reserved. 

Template DKP50047-F-085M 

Reviews: