-7-
No.D-
※
S-OMG0006-C
●
Product handling
Installation
Do not drop or apply impact.
The product may be damaged or malfunction if it is dropped, bumped or applied with excessive impact (the sensor:
980 m/s
2
, the amplifier: 98 m/s
2
).
Observe the required tightening torque for mounting a product.
If a product is tightened beyond the specified tightening torque, the product, mounting screws, or mounting bracket
may be damaged.
Tightening below the specified tightening torque will allow the product to move out of position.
Use only the screws installed in the product body for mounting the product.
If other screws are used, the product may be damaged.
Set the product based on the instructions for the cylinder or actuator.
Mounting the product close to the edge of its operating range (close to the border of ON/OFF operation) may cause
unstable operation. Some actuator and cylinder series have their own setting methods. In such cases, follow the
instructions given.
For products with 2-colour display, the operation may be unstable due to the installation environment and the
effects of disturbance, even if the product is mounted in the correct operating range (green light range). (e.g. close
proximity of actuators with built-in magnet, magnetic substances, external magnetic fields, temperature changes, or
other fluctuating magnetic forces).
Check and adjust the actual product operation during installation.
The product may not operate in the correct actuator mounting position due to the installation environment.
Also check and adjust the product operation when used in intermediate stroke positions, according to the operating
environment.
Ensure that the FG terminal is connected to ground when using a commercially available switch-mode
power supply.
Wiring
Do not pull hard on the cable. In particular, do not carry an actuator by the product cable.
This may cause a broken cable or damage to the product internal elements.
Check the insulation of the wiring.
Check that there is no faulty wiring insulation (short circuits, faulty ground connections, improper insulation between
terminals, etc.), as this may damage the product due to over current.
Do not route the product wiring in the same place as power cables or high voltage cables.
Otherwise product malfunction may result due to noise and inrush current.
Avoid repeatedly bending or stretching the cable.
Wiring with repetitive bending stress or tensile stress can cause broken cable or peel of a sheath. If the cable can
move, fix it near the body of the product.
Turn the power ON after connecting a load.
Other wise it can cause excess current causing instantaneous breakage of the product.
Avoid incorrect wiring
If connections are reversed (power supply wire + and -), the product will be protected by a protection circuit.
However, if the blue wire is connected to the power supply (+) and the black wire is connected to the power supply (-),
the product will be damaged.