Error status details
Code Meaning
0 No
troubles
1
Life of E
2
ROM (cannot write in):
Consult the shop or SMC Corporation.
2
Parity error of E
2
ROM:
Reset memory. Re-input all the data since these are erased after reset.
Note: Text is up to 10 byte. Error status indicates trouble on the counter side.
Troubles can be checked at turning ON the power. Error status is a text data of
1 byte.
⑲
Command error
Response Block
# 0 0 E E
*
*
*
[CR]
Unit No. Command Error Check sum
code
code
When there is an error in the command block that has been sent, the response block above is
sent back to the host computer side. Error code is a text data of 2 byte.
Error Code
Meaning
0
1
Not executed due to count mode
0
2
Not executed due to setting mode
0
3
Set value differs from command format
0
4
No corresponding command
0
5
Not executed due to cylinder stop output OFF
0 6
(Unused)
0 7
(Unused)
0 8
(Unused)
0 9
(Unused)
-