Mounting

Allowable Kinetic Energy

Caution

Selection

Without auto switch

With auto switch

22

When mounting a mini free-mount cylinder, tighten the 
bolts with the proper tightening torque.

CUJB4
C(D)UJB6
C(D)UJB8
C(D)UJB10

Bolt

M2.5 x 0.45

M3 x 0.5

4

3.8 x 10

-3

6

6.25 x 10

-3

8

9.35 x 10

-3

10

12.5 x 10

-3

Bore size (mm)

Operating piston speed (m/s)

Allowable kinetic energy (J)

Proper tightening torque  N

m

0.54

1.06

Tightening torque

Tightening torque

Caution

0

4 6 8 10

15

20

0.4

0.3

0.2

0.1

ø4

ø6

ø8

ø10

Allowable lateral load  W (N)

Allowable lateral load  W (N)

Stroke  ST (mm)

0

4 6 8 10

15

20

ø6

ø8

ø10

Stroke   ST (mm)

0.5

0.4

0.3

0.2

0.1

0.01

0.1

1.0

0.01

0.1

1

10

Maximum speed  V (m/s)

Load weight  kg

0.05 to 0.5

ø4

ø6

ø8

ø10

When driving an inertial load, operate a cylinder with 
kinetic energy within the allowable value. The range in 
the chart below that is delineated by bold solid lines 
indicates the relation between load weights and 
maximum driving speeds.

Strictly observe the limiting range of lateral load on a piston 
rod. (See the graphs below.) If this product is used beyond 
the limits, it may shorten the machine life or cause damage.

Summary of Contents for CDUJB10-20D

Page 1: ...Mini Free mount Cylinder Series CUJ 4 6 8 10 CAT ES20 157 A...

Page 2: ...Stroke b A a B CUJ CU Features 1 Miniature body Dimensions without magnet mm Numbers in parentheses are the dimensions of SMC Series CU cylinders Bore Size 4 6 8 10 A a B b C c 10 13 13 13 13 5 15 15...

Page 3: ...e acting spring return Series CUJ Bore size mm Rod end configuration Stroke mm Clean room series 4 6 8 10 15 20 4 6 8 10 Male thread Without thread Nil Female thread Male thread Solid state switch D F...

Page 4: ...Refer to Table 1 Standard strokes below CUJ B Bore size mm 4 6 8 10 4 6 8 10 Double acting Single acting spring return Standard stroke mm 4 6 8 10 4 6 8 10 15 4 6 8 10 15 20 4 6 4 6 8 4 6 8 10 Table 1...

Page 5: ...2 7 3 0 3 2 Additional weight With magnet Rod end male thread With magnet Rod end male thread 0 4 0 8 1 5 2 6 g Additional weight 2 4 2 5 2 4 0 4 0 8 1 5 2 6 CUJB4 CUJB6 CUJB8 CUJB10 Bore size mm Sta...

Page 6: ...J Mounting Through hole mounting bolts are available for mounting a cylinder To order bolts add CUJ at the beginning of the bolt description Example CUJ M3 x 27L A A C B B For axial mounting Without A...

Page 7: ...ad Number of auto switches Nil S 2 pcs 1 pc Auto switch type Nil Without auto switch built in magnet Bore size 6 8 10 F8N Stroke The specifications are the same as those for the standard double acting...

Page 8: ...JB4 S PS CUJB6 S PS CUJB8 S PS CUJB10 S PS Bore size 4 6 8 10 Contents Above number 11 and an exclusive grease pack Parts list No Description Cylinder tube Rod cover Piston Piston rod Seal retainer Ma...

Page 9: ...ss flats 4 2 5 Element Single acting 4 6 4 M2 x 0 4 1 6 Rod end nut part no NTJ 004 Rod end male thread Note The angular position of the width across flats is not fixed with respect to the tube 10 5 1...

Page 10: ...through Width across flats 8 2 M3 x 0 5 bore size 13 7 3 19 M2 5 x 0 45 effective depth 5 19 Stroke 13 Stroke 6 5 Stroke 3 6 3 5 4 9h9 Width across flats 3 5 9 10 7 7 3 2 5 3 24 Stroke 18 Stroke 11 5...

Page 11: ...Rod end male thread Single acting Element 5 11h9 14 5 8 5 2 5 7 3 2 M4 x 0 7 Width across flats 7 Width across flats 4 5 Rod end nut part no NTJ 010A 3 2 7 8 1 M4 x 0 7 2 3 3 through 2 3 3 through Wid...

Page 12: ...oss flats 11 2 M3 x 0 5 bore size M3 x 0 5 effective depth 6 Width across flats 5 13 5 7 3 2 22 19 Stroke 13 Stroke 6 5 Stroke 3 6 3 5 6 12h9 10 5 11 5 8 5 8 5 3 3 24 Stroke 18 Stroke 11 5 Stroke 3 5...

Page 13: ...bore size 6 cylinders with auto switches keep the switch groove side surface at least 2 5mm away from a magnetic substance If a magnetic substance is closer than 2 5mm auto switches may malfunction d...

Page 14: ...exible specification Example 61 Output Output Old Red Black New Brown Blue 2 wire 3 wire Power supply Power supply GND Output Old Red Black White New Brown Blue Black Lead wire colors of SMC auto swit...

Page 15: ...ircuit Load Blue Black Brown Red Main switch circuit Load Brown Red Blue Black Black White PLC internal circuit COM Switch Input Black White Brown Red Blue Black PLC internal circuit COM Switch Input...

Page 16: ...e Black DC Brown Red DC Blue Black OUT Black White OUT Brown Red OUT Blue Black g Solid State Auto Switches Direct Mount Type D F9N D F9P D F9B D F9N In line NPN 28VDC or less 40mA or less D F9P In li...

Page 17: ...ON 100 A or less at 24VDC OUT Black White DC Brown Red DC Blue Black Main switch circuit DC Brown Red DC Blue Black OUT Black White Main switch circuit Main switch circuit OUT Brown Red OUT Blue Blac...

Page 18: ...ility of having negative effects on people property or animals requiring special safety analysis 15 Series CUJ Safety Instructions Note 1 ISO 4414 Pneumatic fluid power Recommendations for the applica...

Page 19: ...esigned to prevent sudden lurching because there is a danger of human injury and or damage to equipment when this occurs 8 Consider emergency stops Design so that human injury and or damage to machine...

Page 20: ...r or water separator etc Air that includes excessive drainage may cause malfunction of valves and other pneumatic equipment To prevent this install an air dryer after cooler or water separator etc 3 U...

Page 21: ...magnetic fields Maintenance 1 Perform maintenance according to the procedure indicated in the instruction manual If handled improperly malfunction and damage of machinery or equipment may occur 2 Rem...

Page 22: ...olid state switch With a 2 wire solid state auto switch current leakage current flows to the load to operate the internal circuit even when in the OFF state If the above requirement is not satisfied i...

Page 23: ...tact with other circuits ground fault improper insulation between terminals etc Damage may occur due to excess current flow into a switch 4 Do not run wiring near power lines or high voltage lines Wir...

Page 24: ...inu ally exposed to water splash or spray Poor insulation or swelling of the potting resin inside switches may cause mal function 4 Do not use in an environ ment with oil or chemicals Consult SMC if a...

Page 25: ...roper tightening torque N m 0 54 1 06 Tightening torque Tightening torque Caution 0 4 6 8 10 15 20 0 4 0 3 0 2 0 1 4 6 8 10 Allowable lateral load W N Allowable lateral load W N Stroke ST mm 0 4 6 8 1...

Page 26: ...ure 1 below Note Only applicable to the mounting position shown in Figure 1 below Applicable to mounting positions 1 2 3 and 4 Applicable to mounting positions 1 2 and 3 Applicable to mounting positio...

Page 27: ......

Page 28: ...ica Venezuela S A OCEANIA AUSTRALIA SMC Pneumatics Australia Pty Ltd NEW ZEALAND SMC Pneumatics N Z Ltd EUROPE AUSTRIA SMC Pneumatik GmbH CZECH SMC Czech s r o DENMARK SMC Pneumatik A S FINLAND SMC Pn...

Reviews: