40.20 

    

 

The  unit  shall  be  equipped  with  the  SMC 

 

system, which will allow full loads to be processed in a programmable time period that may 
be  less  than  10  minutes.  Treatment  shall  consist  of  a  wash,  using  partially  re-used  wash 
solution, and a rinse using fresh hot water from the Owner’s supply, conducted through an 
on-board  heating  system  and  a  completely  separate  piping  and  spray  header  system.  The 
system shall include PID technology such that the rinse water can be applied and maintained 
at an arbitrarily high temperature up to 205F (96C). Total water usage shall be 15 gallons 
(95L) or less per load. 

 
40.21  Cabinet-Style Door(s) - Cabinet-style, horizontally opening door(s) shall be provided in lieu 

of the standard guillotine-type door(s). Door(s) shall be 2" thick, filled with insulation, and 
shall be gasketed and sealed to prevent leakage of treatment solutions or vapor. This option 
shall be chosen when available heights will not accommodate the standard doors in the open 
position. 

 
40.22  Load  Shelf  Type  Door(s)  -  Load  Shelf  Type  door(s)  shall  be  provided  in  order  to  match 

owner's  existing  operation  and  work  flow.  Doors  shall  be  2"  thick  and  fully  insulated, 
complete with outrigger supports. 

 

50.0 

Available Accessories 

 
50.1 

General Purpose Wash Basket  - A wire mesh basket, 20" x 20" x 5" shall be provided to 
allow small items to be washed safely and efficiently. This basket shall be suitable for sipper 
tubes. 
 

50.2 

Cage Processing Rack - Stainless steel rack shall be provided to process cages of any size or 
shape. Samples shall be provided by the owner at time of order. The rack shall be provided 
as a two-rack system to allow easier loading and handling. 
 

50.3 

Transfer Cart -  A  Stainless  Steel  cart  with  a  plastic  top  shall  be  provided  to  assist  in  the 
loading  and  unloading  of  the  machine  and  the  cage  processing  racks.  Cart shall have  soft 
non-marking tires on stainless steel casters. 

60.0 

Utility Requirements 

 

 

 

Electrical 

3ph, 60hz, 6kw 

Add for Elec 

 

Heat Option 

3ph, 60hz, 24kw 

 

 

Steam 

1 ½ FPT 

 

30-80 PSI 

 

350#/Hr Max Flow 

 

250#/Hr Avg Flow 

 

 

Condensate 

1 FPT 

 

 

Summary of Contents for CBW1026

Page 1: ...ing as well as many features unique to our design 2 0 Dimensions W X H X L W X H X L MODEL DOOR CONFIGURATION CHAMBER SIZE EXTERNAL OVERALL SIZE 1026 VERTICAL LIFT 48 X 32 X 34 72 X 78 X 38 1 2 1026L...

Page 2: ...viously entrained debris shall not be acceptable 4 5 Strainer shall be easily removable with no tools via a sanitary style clamp System shall be completely self regulating and require routine inspecti...

Page 3: ...al 6 5 2 Door Open Lack of positive door closure shall cause the machine to enter Pause mode from where the current cycle can be recovered Fault message shall indicate which door is at fault if the ma...

Page 4: ...shall be programmable from the Color Touch Screen PIN screens shall be available at the discretion of the supervisor to lock out access to the cycle phase programming functions All timers in the prog...

Page 5: ...he last rinse shall be used to remove heavy soil flushing any easily removed matter to drain in order to ensure that the detergent solution stays as clean as possible Treatment shall be under pressure...

Page 6: ...engineered part and sub assembly shall be scrutinized and all specific design decisions shall be made in the light of these basic criteria 30 1 3 All purchased components shall be un modified off of...

Page 7: ...ets shall be elliptical spray jets equal to Spraying Systems Co 1 4USS8030 No proprietary jets shall be acceptable 30 10 Washer programmable control shall provided by a modular industrial type program...

Page 8: ...provided with a door at each end for operation within a clean dirty room environment 40 5 Door Interlocks Doors shall be provided with pneumatically operated door locks arranged such that the two door...

Page 9: ...de for Direct Factory Accessible Programming This option shall allow trained SMC technicians to directly access the programming of the machine from a remote location for changes or diagnostic purposes...

Page 10: ...be chosen when available heights will not accommodate the standard doors in the open position 40 22 Load Shelf Type Door s Load Shelf Type door s shall be provided in order to match owner s existing...

Page 11: ...ry shall be consulted for steam pressures below 30 psi dynamic 60 1 4 Hot water temperatures of less than 180 degrees F may impact treatment cycle times Factory shall be consulted for recommendations...

Page 12: ...BW1026 1026LS 1026C CBW1026L 1026LLS 1026LC Shipping Wgt 2100 2400 Dynamic Wgt as Installed 1800 2000 Cage Capacity Std Mouse 32 48 Std Rat 12 16 Sump Capacity 25 Gals 25 Gals Heat Radiation typ door...

Reviews: