![SMC Networks AW20-B Instruction Manual Download Page 3](http://html1.mh-extra.com/html/smc-networks/aw20-b/aw20-b_instruction-manual_1299511003.webp)
AW-SMU06EN
Page 3 of 4
4 How to Order
5 Outline Dimensions (mm)
5.1 AW20(K)-B
5.2 AW30(K)-B, AW40(K)-B
5 Outline Dimensions (mm)
– continued
5.3 AW60(K)-B
Option
Dimensions
Square embedded type
pressure gauge
Digital pressure switch
Round type pressure gauge
Round type pressure gauge
(with colour zone)
Applicable
model
AW20(K)-B
Optional/Semi-
standard
specifications
With auto drain
(N.C.)
Metal bowl
With drain guide
Dimensions
Drain
(Pressure gauge port size)
C
le
a
ra
n
c
e
f
o
r
m
a
in
te
n
a
n
c
e
IN
OUT
(Port size)
Bracket
(Option)
Panel fitting dimensions
IN
OUT
Plate thickness
AW20(K)-B: Max. 3.5
(Pressure gauge port size)
Drain
C
le
a
ra
n
c
e
f
o
r
m
a
in
te
n
a
n
c
e
IN
IN
OUT
OUT
Panel fitting dimensions
(Port size)
Bracket
(Option)
Plate thickness
AW30(K)-B: Max. 3.5
AW40(K)-B: Max. 5
Bracket
(Option)
(Port size)
Drain
IN
OUT
(Pressure gauge
port size)
C
le
a
ra
n
c
e
f
o
r
m
a
in
te
n
a
n
c
e
Center of
piping
Center of
piping
Center of
piping
Width across
flats 14
AW 30 K
– 03 BE – – B
1
2
3
4
5
6
Symbol
Description
❶
Body size
20
30
40
60
❷
With backflow function
Nil
Without backflow function
K
Note1)
With backflow function
❸
Pipe thread type
Nil
Rc
N
Note 2)
NPT
F
Note 3)
G
❹
Port size
01
1/8
–
–
–
02
1/4
–
03
3/8
–
–
04
1/2
–
–
–
06
3/4
–
–
10
1
–
–
–
❺
O
p
ti
o
n
N
o
te
4
)
a
Mounting
Nil
Without mounting option
B
Note 5)
With bracket
H
With set nut (for panel mount)
–
b
Float type
auto drain
Nil
Without auto drain
C
Note 6)
N.C. (Normally closed) Drain port is closed when pressure is not applied.
D
Note 7)
N.O. (Normally open) Drain port is open when pressure is not applied.
–
c
Pressure
gauge
Note 8)
NIL
Without pressure gauge
E
Square embedded type pressure gauge (with limit indicator)
G
Round type pressure gauge (with limit indicator)
M
Round type pressure gauge (with colour zone)
Digital pressure
switch
Note 9)
E1
Output: NPN output / Electrical entry: Wiring bottom entry
E2
Output: NPN output / Electrical entry: Wiring top entry
E3
Output: PNP output / Electrical entry: Wiring bottom entry
E4
Output: PNP output / Electrical entry: Wiring top entry
❻
S
e
m
i-
s
ta
n
d
a
rd
d
Set pressure
Note 10)
Nil
0.05 to 0.85 MPa setting
1
0.02 to 0.2 MPa setting
e
Bowl
Note 11)
Nil
Polycarbonate bowl
2
Metal bowl
6
Nylon bowl
8
Metal bowl with level gauge
–
C
With bowl guard
–
Note 12)
–
Note 12)
–
Note 12)
6C
Nylon bowl with bowl guard
–
Note 13)
–
Note 13)
–
Note 13)
f
Drain port
Note 14)
Nil
With drain cock
J
Note 15)
Drain guide 1/8
–
–
–
Drain guide 1/4
–
W
Note 16)
Drain cock with barb fitting
–
g
Exhaust
mechanism
Nil
Relieving type
N
Non-relieving type
h
Flow direction
Nil
Flow direction: Left to right
R
Flow direction: Right to left
i
Pressure unit
Nil
Name plate, caution plate for bowl, and pressure gauge in imperial units: MPa
Z
Note 17)
Name plate, caution plate for bowl , and pressure gauge in imperial units: psi, °F
Note 19)
Note 19)
Note 19)
Note 19)
ZA
Note18)
Digital pressure switch: With unit conversion function
Note 20)
Note 20)
Note 20)
Note 20)
Note 1)
Set the inlet pressure to at least 0.05 MPa higher than the set pressure.
Note 2)
Drain guide is NPT1/8 (applicable to the AW20(K)-B) and NPT1/4 (applicable to the AW30(K)-B to AW 60(K)-
B). The auto drain port comes with Ø3/8” One-touch fitting (applicable to the
AW30(K)-B to AW60(K)-B).
Note 3)
Drain guide is G1/8 (applicable to the AW20(K)-B) and G1/4 (applicable to the AW30(K)-B to AW60(K)-B).
Note 4)
Option B, G, H, M are not assembled and supplied loose at the time of shipment.
Note 5)
Assembly of a bracket and set nuts (applicable to the AW20(K)-B to AW40(K)-B). Including 2 mounting screws for the AW60(K)-B.
Note 6)
When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl. Releasing th e residual condensate before ending operations for the day is
recommended.
Note 7)
If the compressor is small (0.75 kW, discharge flow is less than 100
/min [ANR]), air leakage from the drain cock may occur during start of operations. N.C. type is recommended.
Note 8)
When the pressure gauge is attached, a 1.0 MPa pressure gauge will be fitted for standard (0.85 MPa) type. 0.4 MPa pressure g auge for 0.2 MPa type.
Note 9)
When choosing with H (panel mount), the installation space for lead wires will not be secured. In this case, select “wiring top entry” for the electrical entry. (Select “wiring bottom entry” when the
semi-standard Y is chosen simultaneously.)
Note 10) Pressure can be set higher than the specification pressure in some cases, but use pressure within the specification range.
Note 11) Refer to Chemical data in the catalogue for chemical resistance of the bowl.
Note 12) A bowl guard is provided as standard equipment (polycarbonate).
Note 13) A bowl guard is provided as standard equipment (nylon).
Note 14) The combination of float type auto drain: C and D is not available.
Note 15) Without a valve function
Note 16) The combination of metal bowl: 2 and 8 is not available.
Note 17) For pipe thread type: NPT. This product is for overseas use only according to the new Measurement Law. (The SI unit type is p rovided for use in Japan.) Cannot be used with M: Round
pressure gauge (with color zone). Available by request for special. The digital pressure switch will be equipped with the unit conversion function, setting to psi initially.
Note 18) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in Japan.)
Note 19)
: For pipe thread type: NPT only
Note 20)
: Select with options: E1, E2, E3, E4.
Option/Semi-standard: Select one each for
a
to
i
Option/Semi-standard symbol: When more than one
specification is required, indicate in alphanumeric order.
(Example: AW30K-03BE-1N-B)