C) Loosen the hexagon socket head cap screws with a hexagon wrench key while holding the flange
by hand.
After loosening all the bolts, lower the flange to the stopper slowly.
In this operation, fingers should not be pinched between the flange and stopper.
D) When the bowl is rotated in the direction shown by the arrow below, by approximately 10 degrees,
the bowl is removed from the body.
At this time, be careful not to drop the bowl.
Note:
The O-ring for bowl can easily fall off, so replacement should be performed while the bowl
is held upright.
E) Remove the used element and O-ring from the bowl.
In this operation, remove the support ring to make the replacement easier.
D)
Rotate
approxim
ately
10°.
Support
ring
~
Point
~
Replacement should
be performed while
the bowl is held
upright as the O-ring
easily falls off.
O-ring for
bowl
E)
C)
Hold the flange
by hand.
Be careful! Your
hand might be
pinched!!