SMC Networks AFF70D Operation Manual Download Page 10

Doc. no. AMX-OMU0058-C 

-10- 

1-3. Maintenance 

   

Warning 

Perform maintenance inspections according to the procedure indicated in the Operation 

Manual. 

Incorrect handling of the product may cause breakage or malfunction of the equipment or 

device. 

 

Maintenance work 

If handled improperly, compressed air can be dangerous. Assembly, handling, repair and 

element replacement of pneumatic systems should be performed by a knowledgeable and 

experienced person. 

 

Removal of equipment, and supply/exhaust of compressed air. 

         

When equipment is to be removed, first confirm that measures are in place to prevent losing 

control of the equipment or workpieces from falling, etc. Then, shut off the supply air and 

exhaust the compressed air in the system. 

When machinery is restarted, turn off the power supply, stop the air supply and exhaust all 

compressed air from the system. 

 

If an error is generated, turn off the power supply and stop the compressed air supply. 

         

If smoke, abnormal smells or noises are generated, there is a possibility of fire. In that case,   

stop supplying the compressed air and reduce the pressure in the equipment to zero. 

When maintenance of the auto drain is performed, or filter element is replaced, be sure 

to reduce the compressed air to zero. Do not touch the high temperature section. 

         

Using this product at a high temperature (40 to 60 

o

C) may cause burns. Be sure to 

confirm that the temperature of the container or operating part is reduced to 40 degrees 

or less to prevent burns.

 

       

Element service indicator 

         

Perform periodical check to find cracks, flaws or other deterioration. If any are seen, replace 

with new parts and review the operating condition. Otherwise, a malfunction may occur. 

Please consult SMC if the review of the operating conditions is not possible. 

Caution

 

Replace the element with a new one when the replacement timing has come. 

If an element is used even after exceeding the replacement timing, the outlet compressed air 

cleanliness might be reduced or oil mist may leak out, which may damage the element. 

<Element replacement timing> 

When the element service indicator operates or 2 year after starting operation, whichever 

comes first. 

 

2. Be sure to exhaust the drainage that has accumulated in the filter. 

Operation with condensate caught in the equipment or the piping may lead to operation 

failure of the equipment, splashing from the outlet, and unexpected accidents. 

Clean the bowl regularly. 

Clean inside of the bowl with tepid water in which detergent is dissolved (25

 o

C or less),   

and eliminate foreign matter and oil. 

If foreign matter or drain scale is accumulated, it 

could cause operation failure of the auto drain, so please clean it regularly. 

If necessary, remove the auto drain from the bowl before cleaning. Please refer to Auto drain 

replacement on P14 for removal of the auto drain. 

Summary of Contents for AFF70D

Page 1: ...Doc no AMX OMU0058 C 1 PRODUCT NAME Air preparation filter MODEL Series Product Number Main Line Filter AFF70D AFF80D AFF90D Mist Separator AM70D AM80D AM90D Micro Mist Separator AMD70D AMD80D AMD90D...

Page 2: ...autions 5 1 2 Installation Piping 8 1 3 Maintenance 10 2 Application 11 3 Specifications 11 4 How to Order 12 5 Component name and spare parts list 13 6 Troubleshooting 14 7 Assembly and replacement p...

Page 3: ...f equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Page 4: ...he failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are exclu...

Page 5: ...ent An area exposed to direct sunlight Block direct sunlight to the product to prevent deterioration due to ultraviolet rays or temperature rise Where the product is exposed to heat sources or in area...

Page 6: ...cluding deteriorated oil Solid foreign matter or oils including rust in the piping Select the model so that the maximum value instantaneous of the flow rate will not exceed the rated air capacity When...

Page 7: ...ile pressure is left in the filter drainage blows out from the drain port abruptly Note Manual release is not available with the auto drain with 1 6MPa specification The workpiece will be contaminated...

Page 8: ...ffected by excess moment load and vibration from the piping side Use flexible tubing in between to avoid such an effect As a filter is a heavy object please transfer or install it making sure that it...

Page 9: ...connected correctly The compressed air inlet is indicated with a flow direction symbol on the top of the product Drain piping of the auto drain should be performed with an appropriate tube diameter a...

Page 10: ...a high temperature 40 to 60 o C may cause burns Be sure to confirm that the temperature of the container or operating part is reduced to 40 degrees or less to prevent burns Element service indicator...

Page 11: ...et air pressure 0 7MPa Filtration Note 4 1 0 m Filtration efficiency 99 Water droplet elimination factor Note5 99 Note 1 When selecting Option H Option J Note 2 Air flow capacity with 20 o C atmospher...

Page 12: ...o test condition ISO8573 2 2010 and test method ISO12500 1 2007 Oil mist concentration on the filter inlet side 30mg m3 ANR Flow capacity inlet pressure and the Oil mist concentration at the filter in...

Page 13: ...d test method ISO12500 1 2007 Oil mist concentration on the filter inlet side 30mg m3 ANR Flow capacity inlet pressure and the Oil mist concentration at the filter inlet are stable New element Model A...

Page 14: ...3 Option H and Option J cannot be selected simultaneously Air preparation filter Piping port size Symbol Port size Applicable body size 70 80 90 10 1 14 1 1 2 20 2 Model Product Name Symbol Main Line...

Page 15: ...70D 80D 90D Part No 2 Element AFF AFF EL70D AFF EL80D AFF EL90D AM AM EL70D AM EL80D AM EL90D AMD AMD EL70D AMD EL80D AMD EL90D 8 Bracket AM BM70D AM BM90D Service parts No Description Part No 7 Elem...

Page 16: ...ain valve of the auto drain Remove the dust Main valve of the auto drain is broken Replace the auto drain Drain piping is long or I D of the piping is small Back pressure is applied Tube I D should be...

Page 17: ...ghtening torque is 6 2N m for 70D and 12 5 N m for 80D and 90D Warning Be sure to set the pressure to zero before work 7 2 Auto drain replacement Auto drain MAX 1 6MPa cannot be replaced A Rotate the...

Page 18: ...mately 10 degrees the bowl is removed from the body At this time be careful not to drop the bowl Note The O ring for bowl can easily fall off so replacement should be performed while the bowl is held...

Page 19: ...y using a spanner or monkey wrench while lightly holding the internal assembly chamber head Tightening torque of the lock nut is 2N m K Insert the guide and element in order and mount the O ring for t...

Page 20: ...l up the flange and tighten the hexagon socket head cap screws with a hexagon wrench Tightening torque is 12 5N m for 70D and 24 5 N m for 80D and 90D Although there will be a slight gap between the b...

Page 21: ...placement L to M When it is difficult to insert the new element into the body Please apply lubricant to the connection body of the O ring for the element At this time pay attention that lubricant is n...

Page 22: ...92 394 5 38 170 160 80 23 40 AFF AM AMD 90D 1 1 2 2 470 458 460 5 38 170 160 80 23 40 Model Bracket related dimensions H I J K L M N O P AFF AM AMD 70D 124 82 48 4 90 18 9 16 10 2 6 AFF AM AMD 80D 148...

Page 23: ...tember 2018 C Change Flow capacity June 2019 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change...

Reviews: