background image

- 6 - 

 

Air Source

 

       

Warning

 

1)  Use clean air. Do not use compressed air containing chemicals, organic solvent, synthetic oil or 

corrosive gas as it may be cause of breakage of components or operation failure.   

2)  Air containing too much moisture may deteriorate the performance. Install the refrigerated air dryer 

or aftercooler before the line filter. 

3)  Make sure that the supply pressure is not below the minimum operating pressure. If it is used at the 

minimum operating pressure or less, pressure resistance increases, leading to the decrease of 
operation life or operation failure. 

 
 

Maintenance

 

       

Warning

 

1)  Release the pressure in the product to the atmosphere when replacing parts or removing piping.   
2)  Maintenance and checks should be done by following the procedure in the operation manual. 

Incorrect handling of the product may cause breakage or operation failure of the equipment or 
device. 

3)  Do not touch the product when operating at high temperature (40 to 60 

o

C). The operators may get 

burnt. Be sure to confirm that the temperature of the container or operating part is reduced to 40 

o

or less to prevent burns. 

4)  On a product with an element service indicator, perform regular checks to find cracks, scratches, or 

other deterioration of the indicator window. If any crack, scratch, and other defect is observed, 
replace the element service indicator with new a one because such a defect may cause the product 
to be broken. Investigate and/or review the operating conditions if necessary. 

5)  Check for dirt in the bowl periodically. If any dirt is seen, replace with new bowl. 
6)  Open and close drain cock by hand. The use of tools can result in damage to the product. 
7)  Replace the element before 2 years passed from start of use or pressure drop (difference between 

the inlet pressure and outlet pressure) reaches 0.1MPa. Or if the element is broken. 

 

       

Caution

 

1)  Check the element periodically and replace it with a new one if necessary. If it is found that outlet 

pressure drops or the flow is restricted, check the condition of the element.   

2)  For the N.C. type auto drain, when there is no pressure, condensate which does not operate the 

auto drain mechanism will remain in the bowl. It is recommended to release the residual condensate 
manually at the end of the working day.   

3)  Products with an element service indicator show a red indication as the element clogging 

progresses. Ensure that the element is replaced before the red indication reaches the upper limit.   

 
 

 

Summary of Contents for AFF50-06-D

Page 1: ...Doc No AMX OMZ0092 PRODUCT NAME Line Filter MODEL Series Product Number AFF50 F N 06 F N 10 B C D J L R W Z D AFF60 F N 10 B C D J L R W Z D...

Page 2: ...wl assembly for AFF50 10 6 2 Bowl assembly for AFF60 11 7 Assembly of Optional parts 12 8 Operation and Adjustment 13 to 14 8 1 Discharge from the product with drain cock 13 8 2 Manual drain discharge...

Page 3: ...pment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The a...

Page 4: ...ure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded fro...

Page 5: ...t is mounted on the outlet of the product particles will be generated from the equipment and required cleanliness may not be obtained Instead install the air equipment at the inlet Caution 1 Applicati...

Page 6: ...ecommended torque while holding the female thread side tightly Insufficient tightening torque can cause loose piping or sealing failure Excess tightening torque may cause damage to threads If the fema...

Page 7: ...with an element service indicator perform regular checks to find cracks scratches or other deterioration of the indicator window If any crack scratch and other defect is observed replace the element...

Page 8: ...tions Note1 Conditions in accordance with Test method ISO 12500 3 2009 compliant in addition to the conditions The compressed air quality class on the inlet side is 6 8 4 Note4 Based on ISO8573 1 2010...

Page 9: ...Flow direction Left to right R Flow direction Right to left Nil Pressure unit MPa Temp unit o C Z Pressure unit psi Temp unit o F Note2 Note2 e Flow direction f Pressure unit Temperature unit Semi sta...

Page 10: ...t assemblyNote2 Note1 Note2 Part No Part No Refer to 6 Bowl assembly specifications P10 and P11 No Parts description No Parts description AM54P 160S Assembly of the mounting bracket 2 types and set sc...

Page 11: ...o 4 How to Order P8 for option and semi standard symbols 10 W Appearance and Part No D Note2 C Note1 Appearance and Part No Appearance and Part No J Semi standard C Rc G NPT AM54P N120AS C Part No AM5...

Page 12: ...P8 for option and semi standard symbols 11 D Note2 C Note1 W Appearance and Part No Appearance and Part No Appearance and Part No J Semi standard C Rc G NPT AM64P N120AS C Part No AM64P 120AS C Port...

Page 13: ...he bottom of the body Mounting of bracket A see drawing on the left Mounting of bracket B Fix the bracket B with the set screw 2 pcs included in the package Refer to the table below for the tightening...

Page 14: ...t with drain cock 13 Pressurize the inside of the line filter when discharging drain Drain will not be discharged properly if not pressurized Drain cock AFF50 AFF60 Drain cock With barb fitting push t...

Page 15: ...ain will not be discharged properly if not pressurized To discharge the auto drain manually follow the procedure below After discharging the drain rotate the cock to the opposite direction by hand to...

Page 16: ...gn matter is caught at the main valve of the auto drain Remove the dust by manual drain discharge P14 4 Main valve of the auto drain is broken Replace the bowl assembly P16 5 Drain piping is long or I...

Page 17: ...th fingers two locations of the bowl with the body 6 Install the flange to the body temporarily tighten four mounting screws and then tighten them diagonally and evenly to secure the flange AFF50 AFF6...

Page 18: ...owl assembly by referring to the section 10 1 Bowl assembly Replacement P16 Assembly 2 Install the replacing element and bowl seal in the bowl assembly Mount the bowl assembly by referring to the sect...

Page 19: ...11 Disassembly Drawing 18 I N Body OUT AFF50 AFF60 Bowl seal Element Bowl assembly Mounting screws 4 pieces...

Page 20: ...52 5 259 2 AFF60 1 90 314 8 32 45 30 45 70 66 40 5 11 13 113 3 2 52 5 336 3 Model No Option specifications With auto drain Bracket mount Standard specifications B B W AFF50 246 2 244 5 64 3 AFF60 323...

Page 21: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacture...