background image

- 4 - 

 

Precautions for Design

 

       

Warning

 

1)   Carefully consider the application, required specifications, and operating conditions (pressure, flow 

rate, temperature, environment and power supply) in accordance with the latest catalog (SMC 
website), making sure not to exceed the specification range. 

2)  Consult SMC if no leakage is allowed due to the environment, or if the operating fluid is not air.   
3)  This product cannot be used in the following environments.   

- Atmosphere containing corrosive gas, organic solvent, or chemical agent solution is, or a location 

where any of these substances is attached.   

- Atmosphere containing with sea water or water or containing steam, or a location where any of 

these substances is attached.   

- Locations subject to direct sunlight (Block direct sunlight to the product to prevent deterioration due 

to ultraviolet rays or temperature rise).   

- Where the product is exposed to heat sources or in areas that the product is exposed to radiant 

heat.   

- Where impact or vibration is present.   
- In a location with high humidity and a large quantity of dust.   
- Outdoor.   
- Mounting on vehicle or vessel (The product may be damaged due to excessive vibration).   
Note) The display window of the element service indicator of semi standard products is made of 

nylon. 

4)  For air blow applications, prevent airborne particles from the operating environment entering into the 

compressed air stream, or foreign matter may adhere to the workpiece during the air blow. 

5)  If the air equipment is mounted on the outlet of the product, particles will be generated from the 

equipment and required cleanliness may not be obtained. Instead, install the air equipment at the 
inlet.   

 

       

Caution

 

1)  Applications in which the difference between the inlet and outlet pressure exceeds 0.1MPa must be 

avoided. Or the element is broken.   

 
 

Selection

 

       

Warning

 

1)  Grease is used on the internal sliding parts and seals. The grease may flow to the outlet side. If this 

is not acceptable, please consult SMC. 

2)  Select the model so that the maximum discharge value (instantaneous) of the flow rate will not 

exceed the rated air capacity. If the flowrate exceeds the maximum air flow capacity, it may cause 
spillage of drainage and oil to the outlet side, and damage equipment downstream. 

3)  N.O. type auto drain should be operated under the following conditions to avoid operating failure. 

Operating compressor: 0.75kW or more. Discharged flow rate: 100L/min (ANR) or more. When 
using 2 or more auto drains, multiply the value above by the number of auto drains to find the 
capacity of the compressors you will need. For example, when using 2 auto drains, 1.5kW (200L/min 
(ANR)) of the compressor capacity is required. The operating pressure should be 0.1 MPa or more.   

4)  Use the N.C. type auto drain at the operating pressure of 0.15MPa or higher to prevent malfunction.   

 

       

Caution

 

1)  Do not use the product with low air pressure (e.g. for blower). This product is dedicated for 

compressed air whose minimum operating pressure is specified depending on the equipment. If the 
product is operated at a pressure lower than the minimum operating pressure, it may cause 
deterioration in the performance or malfunction. 

 
 
 
 
 

Summary of Contents for AFF50-06-D

Page 1: ...Doc No AMX OMZ0092 PRODUCT NAME Line Filter MODEL Series Product Number AFF50 F N 06 F N 10 B C D J L R W Z D AFF60 F N 10 B C D J L R W Z D...

Page 2: ...wl assembly for AFF50 10 6 2 Bowl assembly for AFF60 11 7 Assembly of Optional parts 12 8 Operation and Adjustment 13 to 14 8 1 Discharge from the product with drain cock 13 8 2 Manual drain discharge...

Page 3: ...pment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The a...

Page 4: ...ure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded fro...

Page 5: ...t is mounted on the outlet of the product particles will be generated from the equipment and required cleanliness may not be obtained Instead install the air equipment at the inlet Caution 1 Applicati...

Page 6: ...ecommended torque while holding the female thread side tightly Insufficient tightening torque can cause loose piping or sealing failure Excess tightening torque may cause damage to threads If the fema...

Page 7: ...with an element service indicator perform regular checks to find cracks scratches or other deterioration of the indicator window If any crack scratch and other defect is observed replace the element...

Page 8: ...tions Note1 Conditions in accordance with Test method ISO 12500 3 2009 compliant in addition to the conditions The compressed air quality class on the inlet side is 6 8 4 Note4 Based on ISO8573 1 2010...

Page 9: ...Flow direction Left to right R Flow direction Right to left Nil Pressure unit MPa Temp unit o C Z Pressure unit psi Temp unit o F Note2 Note2 e Flow direction f Pressure unit Temperature unit Semi sta...

Page 10: ...t assemblyNote2 Note1 Note2 Part No Part No Refer to 6 Bowl assembly specifications P10 and P11 No Parts description No Parts description AM54P 160S Assembly of the mounting bracket 2 types and set sc...

Page 11: ...o 4 How to Order P8 for option and semi standard symbols 10 W Appearance and Part No D Note2 C Note1 Appearance and Part No Appearance and Part No J Semi standard C Rc G NPT AM54P N120AS C Part No AM5...

Page 12: ...P8 for option and semi standard symbols 11 D Note2 C Note1 W Appearance and Part No Appearance and Part No Appearance and Part No J Semi standard C Rc G NPT AM64P N120AS C Part No AM64P 120AS C Port...

Page 13: ...he bottom of the body Mounting of bracket A see drawing on the left Mounting of bracket B Fix the bracket B with the set screw 2 pcs included in the package Refer to the table below for the tightening...

Page 14: ...t with drain cock 13 Pressurize the inside of the line filter when discharging drain Drain will not be discharged properly if not pressurized Drain cock AFF50 AFF60 Drain cock With barb fitting push t...

Page 15: ...ain will not be discharged properly if not pressurized To discharge the auto drain manually follow the procedure below After discharging the drain rotate the cock to the opposite direction by hand to...

Page 16: ...gn matter is caught at the main valve of the auto drain Remove the dust by manual drain discharge P14 4 Main valve of the auto drain is broken Replace the bowl assembly P16 5 Drain piping is long or I...

Page 17: ...th fingers two locations of the bowl with the body 6 Install the flange to the body temporarily tighten four mounting screws and then tighten them diagonally and evenly to secure the flange AFF50 AFF6...

Page 18: ...owl assembly by referring to the section 10 1 Bowl assembly Replacement P16 Assembly 2 Install the replacing element and bowl seal in the bowl assembly Mount the bowl assembly by referring to the sect...

Page 19: ...11 Disassembly Drawing 18 I N Body OUT AFF50 AFF60 Bowl seal Element Bowl assembly Mounting screws 4 pieces...

Page 20: ...52 5 259 2 AFF60 1 90 314 8 32 45 30 45 70 66 40 5 11 13 113 3 2 52 5 336 3 Model No Option specifications With auto drain Bracket mount Standard specifications B B W AFF50 246 2 244 5 64 3 AFF60 323...

Page 21: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacture...