background image

11.5

20

4.5

6.5

15

47.2

4.5

1.6

40

30

55

12.1

44.3

1.6

45

4.5

20

6.5

4.5

4.5

30

30

ZSE40A(F)/ISE40A-W1-

-

A

ZSE40A(F)/ISE40A

-WF1-

-

A

With bracket

ZSE40A(F)/ISE40A-W1-

-

B

ZSE40A(F)/ISE40A

-WF1-

-

B

With bracket

Dimensions

8

Series 

ZSE40A(F)/ISE40A

Summary of Contents for 70345470

Page 1: ...y Copy Easy handling Raised rubber switch buttons for easy and comfortable operation See abnormal values at a glance See abnormal values at a glance See abnormal values at a glance IP65 compliant RoHS compliant Applicable fluid Can Can copy copy to up to to up to 10 10switches simultaneously switches simultaneously Can copy to up to 10switches simultaneously Master pressure switch source of copy 1...

Page 2: ...optional 3 digit value is entered Secret code setting function A function to prevent operation by anyone other than the designated operator while the keys are locked Power saving function The display can be turned off to save the power consumption Power consumption reduced by max 20 Resolution conversion function The flickering on the display can be eliminated MPa kPa switching function The indica...

Page 3: ...W1 WF1 M5 C4 C6 Panel mount adapter Front protective cover E F Nil Piping specifications 01 N01 W1 WF1 M5 C4 C6 01 N01 Some options are unavailable depending on the piping specifications Refer to Combination of piping specifications with option 1 and part numbers of options When optional parts are required separately use the following part numbers to place an order Refer to page 17 for details Mad...

Page 4: ...teresis mode Window comparator mode Voltage output Analog output Current output Output voltage Rated pressure range Linearity Output impedance Output current Rated pressure range Linearity Load impedance Enclosure Operating temperature range Operating humidity range Withstand voltage Insulation resistance Vibration resistance Impact resistance ZSE40AF compound pressure ISE40A positive pressure Not...

Page 5: ...en display or switch between green and red according to the output Four different display settings are available Lights up when OUT1 is turned ON Output OUT1 display Orange Lights up when OUT2 is turned ON Output OUT2 display Orange Use this button to change the mode or confirm the set value SET button Use this button to select the mode or increase the ON OFF set value It is also used for switchin...

Page 6: ...lue DC White Black White Black White OUT2 Gray Analog output 12 to 24 VDC 12 to 24 VDC 12 to 24 VDC Black Black White White Black White Gray Analog output Copy terminal 12 to 24 VDC 12 to 24 VDC Black White Gray Analog output Gray Auto shift input Analog output 12 to 24 VDC Auto shift input Main circuit R NPN 2 outputs Analog voltage output Max 28 V 80 mA Residual voltage 1 V or less Load Load Bro...

Page 7: ... 8 8 Atmospheric vent port ø2 6 14 7 30 30 10 ø3 5 8 8 Atmospheric vent port ø2 6 W1 Rc1 8 WF1 G1 8 12 14 7 6 2 38 2 26 2 4 19 7 2 x M4 x 0 7 thread depth 4 20 W1 Rc1 8 WF1 G1 8 R 6 5 20 Dimensions ZSE40A F ISE40A 01 ZSE40A F ISE40A N01 ZSE40A F ISE40A W1 ZSE40A F ISE40A WF1 5 Series ZSE40A F ISE40A 2 Color Display High Precision Digital Pressure Switch ...

Page 8: ...M5 2 x 4 5 20 30 32 3 30 10 22 15 28 15 44 3 14 7 28 2 41 2 7 8 5 One touch fitting ø4 ø6 M5 x 0 8 thread depth 5 12 8 8 19 25 4 Dimensions ZSE40A F ISE40A C4 ZSE40A F ISE40A C6 6 Series ZSE40A F ISE40A ...

Page 9: ...7 5 22 7 2 4 2 11 5 15 43 2 40 20 30 20 55 1 6 35 ZSE40A F ISE40A 01 A ZSE40A F ISE40A N01 A With bracket ZSE40A F ISE40A 01 D ZSE40A F ISE40A N01 D With bracket Dimensions 7 Series ZSE40A F ISE40A 2 Color Display High Precision Digital Pressure Switch ...

Page 10: ...5 15 47 2 4 5 1 6 40 30 55 12 1 44 3 1 6 45 4 5 20 6 5 4 5 4 5 30 30 ZSE40A F ISE40A W1 A ZSE40A F ISE40A WF1 A With bracket ZSE40A F ISE40A W1 B ZSE40A F ISE40A WF1 B With bracket Dimensions 8 Series ZSE40A F ISE40A ...

Page 11: ...4 5 7 5 4 2 7 2 22 11 5 15 47 2 1 6 40 30 55 35 ZSE40A F ISE40A W1 D ZSE40A F ISE40A WF1 D With bracket Dimensions 9 Series ZSE40A F ISE40A 2 Color Display High Precision Digital Pressure Switch ...

Page 12: ...o 5 38 6 40 51 2 7 5 25 2 46 7 Panel thickness 1 to 5 38 6 43 6 ZSE40A F ISE40A 01 E ZSE40A F ISE40A N01 E Panel mounting ZSE40A F ISE40A 01 F ZSE40A F ISE40A N01 F Panel mounting Front protective cover Dimensions 10 Series ZSE40A F ISE40A ...

Page 13: ... 2 Panel thickness 1 to 5 38 6 43 6 ZSE40A F ISE40A W1 E ZSE40A F ISE40A WF1 E Panel mounting ZSE40A F ISE40A W1 F ZSE40A F ISE40A WF1 F Panel mounting Front protective cover Dimensions 11 Series ZSE40A F ISE40A 2 Color Display High Precision Digital Pressure Switch ...

Page 14: ...29 2 38 6 51 2 40 7 5 44 7 29 2 Panel thickness 1 to 5 38 6 43 6 ZSE40A F ISE40A C4 E ZSE40A F ISE40A C6 E Panel mounting ZSE40A F ISE40A C4 F ZSE40A F ISE40A C6 F Panel mounting Front protective cover Dimensions 12 Series ZSE40A F ISE40A ...

Page 15: ... n pcs 1 Note This is the minimum value for the piping method 01 or N01 Take the piping material and tubing into account for design When the corner is to have radius it must be R3 or less Panel fitting dimensions Dimensions 13 Series ZSE40A F ISE40A 2 Color Display High Precision Digital Pressure Switch ...

Page 16: ...sure sensor can be made within the range of 5 of the read value The scattering of the indicated value can be eliminated Suction Verification P_1 P_2 A A B 4 n_1 n_2 B A B 4 P_1 or P_2 H_1 or H_2 H_1 H_2 A B 2 Formula for Obtaining the Set Value A Copy function F97 The settings of the master pressure switch can be copied to the slave pressure switches This can reduce the labor for setting and preve...

Page 17: ...ied pressure error System error Remedy Load current of switch output OUT1 exceeds 80 mA Turn the power off and remove the output factor for the overcurrent Then turn the power on Reset applied pressure to a level within the set pressure range The controller does not respond to the auto shift signal Check the equipment and machinery for this point Perform zero clear operation again after restoring ...

Page 18: ...ithout button operation for 30 seconds It is set to the normal mode Power saving mode is OFF when ex factory Decimal points and operation indicator light only when the switch output is turned ON blink in the power saving mode K Secret code setting F81 It can be set whether secret code input is required or not when key is locked It is set to input no secret code when ex factory Rectified value When...

Page 19: ...ping specifications Output specifications Option How to Order ZSE40A F ISE40A X531 Output specifications X NPN open collector 2 outputs Y PNP open collector 2 outputs Pin arrangement Lead wire length 3 m 1 Symbol X501 M12 4 pin pre wired connector 2 Symbol X531 Series ZSE40A F ISE40A Made to Order Please contact SMC for detailed dimensions specifications and lead times 17 ...

Page 20: ...assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to remove product and machinery equipment until safety is confirmed 1 The inspection and maintenance of machinery equipment should only be performed after measures to prevent falling or runaway of the driven obj...

Page 21: ...ment product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad...

Page 22: ...used make sure that the F G terminal is grounded Caution 1 This pressure switch is CE marked however it is not equipped with surge protection against lightning Lightning surge countermeasures should be applied directly to system components as necessary 2 This pressure switch does not have an explosion proof rating Never use in the presence of an explo sive gas as this may cause a serious explosion...

Page 23: ...e specifications accuracy linearity etc on the switch Although it is possible to set a value outside the rated pressure range the specifications will not be guaranteed even if the value stays within the set pressure range Caution Set Pressure Range and Rated Pressure Range Rated pressure range of switch Set pressure range of switch Switch 14 5 psi 0 14 5 psi 72 5 psi 145 psi Pressure range For com...

Page 24: ... contact mounting With display calibration function Simultaneous copying is possible for maximum 10 units IP40 Series Features ZSE80F ZSE80 ISE80 ISE80H Type Rated pressure range Compound pressure Vacuum pressure Positive pressure Positive pressure 14 50 to 14 50 psi 0 00 to 14 65 psi 14 5 to 145 0 psi 14 5 to 290 psi Suitable for a wide variety of fluids with stainless diaphragm IP65 RoHS complia...

Page 25: ...SINGAPORE SMC Pneumatics S E A Pte Ltd SOUTH KOREA SMC Pneumatics Korea Co Ltd TAIWAN SMC Pneumatics Taiwan Co Ltd THAILAND SMC Thailand Ltd NORTH AMERICA CANADA SMC Pneumatics Canada Ltd MEXICO SMC Corporation Mexico S A DE C V USA SMC Corporation of America SOUTH AMERICA ARGENTINA SMC Argentina S A BOLIVIA SMC Pneumatics Bolivia S R L BRAZIL SMC Pneumaticos do Brazil Ltda CHILE SMC Pneumatics Ch...

Reviews: