HARDWARE INSTALLATION – CALIBRATION
13
Retry
Press and hold panic and shutter button
simultaneously more than 2 sec for calibration
Press any single button to escape
Park vehicle on a flat surface with
at least 50 meters of space directly ahead
and press panic button once
G-Sensor Calibration is finished successfully
Press any button or wait 30 seconds to reboot
If G-Sensor Calibration has failed,
Park vehicle on a flat surface with
At least 5 meters of space directly ahead
And press panic button once again
Move directly forward and accelerate vehicle till beep
sound occur
9) After power cables and trigger cables are properly connected and the
BX4000 system is installed, The internal G-Sensor must be calibrated. It
detects the installed direction of the BX4000 (vertically or horizontally) for it to
accurately record the journey direction.
Press and hold [PANIC] & [SHUTTER] button together and then power on
(turn on ignition).
This G-Sensor calibration is only needed at the first time the BX4000 is used.
Panic Button