Smartwares RM220 Manual Download Page 3

Remove

Remove

1

2

Activate

Activate

50cm

50cm

50cm

50cm

50cm

50cm

50cm

10

0c

m

50cm

WAND

CEILING

DO NOT INSTALL ON THE WALL!

4

3

Turn to leftside to open,

to the rightside to close.

7

8

5

CEILING

CEILING

MOUNTING

TESTING 

PRODUCT INFORMATION

INSTALATION

ACTIVATION

(

)

ALARM SILENCE  hush mode

The alarm should not be installed in:

*  A space where the temperature can drop below 4 and 

above 38°C

*  In humid areas.
*  Right next to doors or windows and not near 

a fan or radiator. 

Do not install the alarm in a place with difficult access, which 
could make it difficult to operate the test button and 
maintenance. The alarm can be installed quickly and easily. 
Install the base plate on the selected location using the 
provided screws. 

*  Activate the smoke alarm device before mounting (see 

picture 

1+2

).

*  Take the fixation pin out of the ground plate (

3

).

*  Screw the mounting plate with 2 screws on the celling (

4

).

*  Fix the smoke alarm device on the mounting plate by 

turning, till you hear a “click” (

5

).

*  Put the fixation pin in the hole (

6

).

*  Test the smoke alarm by pushing the TEST button (

7

).

Test the unit to ensure proper operation by pressing the TEST 
button, this will sound the alarm if the electronic circuitry, horn, 
and battery are working. If no alarm sounds, there is a 
defective battery or other failure.

The smoke alarm device, if properly installed and maintained, 

DO NOT:

Use an open flame to test your alarm, you could 

sounds the alarm at an early stage of the fire. This can give 

damage the alarm or ignite combustible materials and start a 

you those extra valuable seconds to evacuate your home and 

fire.

call the fire department. The smoke alarm device works with an 

CAUTION :

 Due to the loudness (85 decibels) of the alarm. 

3x 3V lithium battery. Under normal conditions the service life 

Always stand an arms-length always from the unit when 

of the battery is up to 10 years. When the battery is (almost) 

testing. Test the alarm weekly to ensure proper operation. 

empty, the smoke detector indicates this by an audible “beep”. 

Erratic or low sound coming from your alarm may indicate a 

This indicator sounds every 30-40 seconds during minimum 30 

defective alarm. 

days. End of life, replace complete smoke alarm device!

NOTE

:  Weekly testing is requiered

1.  Make/model number:

 Smartwares RM220

2.  Power supply:

 3x 3V DC CR123A Lithium 

(not replaceable battery)

What is the best place to mount a smoke alarm device:

3.  Scope of application:

 Smoke alarm device for buildings 

*  In the middle of the ceiling, at least 50cm from every edge.

with residential function 

* At least one on each floor.

4.  Function:

 Gives a warning when smoke caused by 

* In every bedroom.

a fire is detected.

*  In the hallway and stairwell.
*  On the landing.

5.  Description:

 Smoke alarm device based on the photocell 

*  In the living room.

principle, which means that the alarm monitors the air for 

* In the storage room or rooms with electrical appliances.

smoke caused by fire. Smoke alarm device does not detect 
heat, gas or fire.

6.  Advice:

 Keep these instructions in a safe, easily 

accessible place.

7.  Caution:

 The alarm is designed in order to detect smoke; it 

cannot prevent a fire. The smoke alarm device should not 
be painted. Protect the smoke alarm device from dust 
during renovation work. The smoke alarm device should not 
be taped/covered (this causes loss of functionality).

8. Caution:

 Keep out of the reach of children.

9. Recommendation:

 Increase the detection area by 

installing several smoke alarm devices

* Remove paper and press (see picture 

1+2

) to 

activate the detector. 

* Leave the smoke detector at rest for about 5 minutes after 

inserting the battery, so the detector can calibrate itself. 

* After activating the battery, it is possible that  the detector 

automatically goes into the "Silent" mode. 

During the smoke alarm is alarming, you push the STILL 

* This gives a beep every 30 seconds, the detector exits this 

button (

8

), it will be paused the smoke alarm alarming for 

mode after about 5 minutes. 

approx. 5 minutes. Smoke alarm devices are designed to 

* If the battery is empty or almost empty the smoke detector 

minimize nuisance alarms. Combustion particles from cooking 

will indicate this with an audible “beep”. 

may set off the alarm if the alarm is located close to the 

* This indicator sounds continually with intervals of 30-40 

cooking area. Large quantities of combustible particles are 

seconds for at least 30 days. 

generated from spills or when grilling/frying. Using the fan on a 
range hood that vents to outside (non-recirculating type) will 
also help remove these combustible particles from the kitchen.

SMOKE DETECTOR RM220

ENGLISH

ALDI Artikel-Nr.: 5745

ALDI Artikel-Nr.: 5745

Pleasae read manual before use and store it

carefully for future use and maintenance

Reviews: