background image

 

HSM-300Z 

Z-Wave Curtain Control Adapter

 

 

Associate to the Zone Key of the HSK-100Z

 

 

The HSM-300Z can associate to the zone key of the HSK-100Z, and execute the turn on/off by 

HSK-100Z. Please follow the steps to associate device: 

 

 

1. Including the HSM-300Z to HSK-100Z. (Please follow the 3.1. Inclusion.)

 

2. Press "ADD" button in Zone Setup keypad.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

3. Select one of group number 1-8.

 

4. The OK LED will be on.

 

5. Press the program button of HSM-300Z.

 

6. Press & release the on/off button which you selected from group number, and you can control

 

the HSM-300Z.

 

 
 

Associate with SD-400Z

 

 

The SD-400Z can connect with HSM-300Z through Z-Wave controller. The SD-400Z has 4

 

groups, and we can use group 1 & 3 to associate the HSM-300Z. Please following the steps to

 

associate:

 

 

1. Please reversed HSK-100Z to the back panel, and open the case.

 

2. Press "ADD" button in Advance Setup keypad.

 

3. Press "ASSOC" button.

 

4. Select group number (1) or (3).

 

5. Press the program button of HSM-300Z.

 

6. Press the program button of SD-400Z.

 

 
 

4. Digital output mode

 

 

Under the digital output mode, the BASIC is mapped to SWITCH MULTILEVEL.

 

 

Change the output manually

 

We can use the button in the rear panel to change the output. In the digital output mode, we 

Status 
LED A 

Status 
LED B 

Reviews: