Step 4: Audible Alarm On  /Off  (default is On) 

  

The display will now show: 
 

 
 
 
 
 
Press the Enter Key, if the Alarm is On this will turn it Off if its Off this will turn it On 
 
 
 

Step 5: Pump Off  

 

 

The display will now show: 

 

 
 
 
 
 
The Pump Off point is the point where the Pump will turn Off. E.g. almost or empty, almost or full 
Use the Scroll or Mute key to move the Pump Off point to the desired level. Press the Enter key to set this as 
your Pump Off point.  

If the Pump key is pressed the pump output will turn on and automatically turn Off 
when the Pump Off point is reached. 
 
If the tank name is either Black or Grey the pump will stop when the tank is equal to 
or less than the programmed stop point. 
 
If the tank name is either Fresh or Fuel the pump will stop when the tank is equal to 
or greater than the programmed stop point. 
 

 

 
Disable Toilet: 
 

If you want to use the Alarm Output as a Toilet Disable control instead of an Alarm then from the Set-Up 
Menu 

scroll down to “Toilet En/Dis” then press the Enter key. Repeat if you want to turn back into an Alarm 

output.

  

 

 

 
Exit Menu

 

 
Scroll to Exit and push the Enter key

 

 
 

 
 
 
 
 

 

Alarm On/Off      

Set Pump Off 

10%       

Summary of Contents for TD-1000

Page 1: ...TD 1000 Tank Monitor Installation Manual...

Page 2: ...300Ma 12vdc Pump output 4 Amps 12vdc Size 65mm x 65mm x 80mm Deep Data Retention 50 years without power Outputs Pump Output 4 Amps 12vdc The TD 1000 has one output which can be used to control an int...

Page 3: ...3 TD 1000 Wiring Red Battery Black Sensor Black Buzzer Blue Buzzer White Output Green Sensor In Black Battery Purple Sensor Connector Mounting 50mm Size 75mm x 75mm Drill a hole using a 50mm hole saw...

Page 4: ...te Relay Toilet Disable Connection Toilet Pump Toilet Pump Blue wire Relay Toilet Disable Connected to SmartSwitch Toilet controller connect blue output wire to SmartSwitch STS 220 toilet controller a...

Page 5: ...ush the Enter button to select the tank Name or scroll to another name PLEASE SEE PAGE 8 FOR SENSOR CALIBRATION Step 3 Setting the Alarm point The display will now show The alarm point is the point wh...

Page 6: ...ed the pump output will turn on and automatically turn Off when the Pump Off point is reached If the tank name is either Black or Grey the pump will stop when the tank is equal to or less than the pro...

Page 7: ...e adaptor is attached make sure that the hole in the adaptor is clear of any excess glue Allow drying as per the instructions for the glue Wrap the threads of the sensor using Teflon plumbers tape and...

Page 8: ...roll to switch between them then press the Enter key Two different methods of tank programming are available if using the pressure sensor 2 Point Calibration sets tank low and high points which can on...

Page 9: ...ing Level Please Wait The display will now show Fill the tank to the TANK HIGH LEVEL Wait for approx 60 seconds for the fluid to settle and press the Enter key The display will show Setting Level Plea...

Page 10: ...show Fill the tank to the 1 4 LEVEL Wait for approx 60 seconds for the fluid to settle and press the Enter key The display will show Setting 1 4 Please Wait The display will now show Fill the tank to...

Page 11: ...ation Tips Tricks on our web site www smartswitch co nz Table 1 SmartSwitch strongly recommends that Table 1 be used to record voltages for each tank level at time of tank calibration These voltages w...

Page 12: ...design and Intellectual Property is owned by Penguin Electronics Ltd Po Box 272 Waikanae New Zealand Ph 0064 4 293 4201 Fax 0064 4 293 4201 Mobile 0064 274 919 805 Email info smartswitch co nz Web ww...