SmartSafe iSmartINC 605 Instruction Manual Download Page 8

Control Panel

Installation & Connection

1) Move the machine onto the workbench after unpacking and loosen the strips on the outlet hoses.

2) Take the adjusting bolt out from the kit and install it to the press plate on the top of the glass tube.

3) Take the fuel distributor from the kit and install it on the knurled nuts and tighten them with the pressing

nut.

4) Take the power cable out from the kit and insert it into the input socket at the bottom of the unit.

First Use (Or reuse after long time storage)

For the new machine, or reusing after long-time storage, the pipeline of the machine is empty and the fuel

pump is not with lubrication. When it starts to work, the fuel pressure may be difficult to establish. Now, you

should do as following:

1) Fill enough test liquid into the tank of the machine.

2) Connect the test adaptor to the outlet pipe and insert it into the

Fill Port

.

3) Power on, select the

System Function,

and then select the

First Use

function.

4) Run it.

5) When there have liquid out from the test adaptor, stop it. If not stop, it’ll stop automatically after 30s.

iSmartINC 605 Injector Cleaner & Tester

6) Now it can use normally.

Note: if there have no liquid out, you can run it again.

Operating Procedures

Preparation

1) Remove the injector from the engine to check the O-rings inside for damage. If it is be damaged need to

replace it. Put the outside of injector in gasoline or detergent, and wipe them with soft cloth after cleaning

the outside oil sludge carefully.

2) Check the test liquid level to be sure there are enough test liquid inside tank. Pouring test liquid from the

port at the top left side of the unit and watch the liquid level in the fuel level viewer. In most cases, filled the

liquid up to 1/2 of the tank capacity.

Function icon

Function

description

Drain for Ultrasonic

Drain for test tubes

Summary of Contents for iSmartINC 605

Page 1: ...iSmartINC 605 Injector Cleaner Tester i iSmartINC 605 Injector Cleaner Tester...

Page 2: ...s rated for lower current than that of the equipment may overheat e Always unplug equipment from electrical outlet when the machine is not in use Never pull the cord when unplugging from the outlet f...

Page 3: ...list Introduction 2 Functions 2 Features Specifications Structure Overview Control Panel Installation Connection First Use Or reuse after long time storage Operating Procedures Preparation Cleaning t...

Page 4: ......

Page 5: ...eaning to remove the carbon deposition on vehicle Setting To set the system language Inquire To check the equipment usage information Information To check the hardware and software version Features Ad...

Page 6: ...t left cover 9 Drain port for ultrasonic cleaner 10 Cabinet front cover 11 Cabinet operate cover 12 Compression screw 13 Fuel distributor 14 Top supply connector 15 Glass tube 16 Pressure gauge 17 Doo...

Page 7: ...ht cover 33 Screw 34 Cool fan 35 Fuel tank 36 Backplane 37 Cabinet back cover 38 Pulse signal line base 39 Screw 40 Solenoid valve bracket 41 Air solenoid valve 42 Draining solenoid valve 43 Bracket 4...

Page 8: ...the test adaptor to the outlet pipe and insert it into the Fill Port 3 Power on select the System Function and then select the First Use function 4 Run it 5 When there have liquid out from the test a...

Page 9: ...Statement the equipment can be operated normally without connecting compressed air This function is only to enhance the test and cleaning effect Note this function is OFF by default We specially desig...

Page 10: ...ter control panel with soft cloth 4 Drain the test liquid from the tank into a container to avoid volatilization Store the test liquid in a safe place if it can be used again or dispose of it in accor...

Page 11: ...Otherwise damage may be incurred Do not let the pulse signal cables or plug dip in the injector s body into the detergent Uniformity Sprayability Test Uniformity test is to find out the difference of...

Page 12: ...yability Test 1 Before doing leakage test please press DRAIN icon to drain the rudimental residual test liquid from the measuring cup 2 Select Leakage Test function and press ENTER key to run At this...

Page 13: ...utlet hoses throttle and combustion chamber So the fuel supply system combustion chamber and injector of the engine must be cleaned on a timely basis Combustion Chamber cleaning is a solution that can...

Page 14: ...transportation D To prevent the unit from shocking and knocking make sure it is on the base seat and in the packing case during transportation Firstly pack the unit with the matter similar with plasti...

Page 15: ...rings continually when there is no fuel pressure The machine has fuel lack warning function and it will ring when the liquid in the fuel tank is lack and then automatically switch off the fuel pump a...

Page 16: ...ble to general repair Under the state of turning on the power the electrical system inside the unit contains the factor causing danger Failure to comply with these instructions could result in death o...

Reviews: