4
Control Panel
Installation & Connection
1) Move the machine onto the workbench after unpacking and loosen the strips on the outlet hoses.
2) Take the adjusting bolt out from the kit and install it to the press plate on the top of the glass tube.
3) Take the fuel distributor from the kit and install it on the knurled nuts and tighten them with the pressing
nut.
4) Take the power cable out from the kit and insert it into the input socket at the bottom of the unit.
First Use (Or reuse after long time storage)
For the new machine, or reusing after long-time storage, the pipeline of the machine is empty and the fuel
pump is not with lubrication. When it starts to work, the fuel pressure may be difficult to establish. Now, you
should do as following:
1) Fill enough test liquid into the tank of the machine.
2) Connect the test adaptor to the outlet pipe and insert it into the
Fill Port
.
3) Power on, select the
System Function,
and then select the
First Use
function.
4) Run it.
5) When there have liquid out from the test adaptor, stop it. If not stop, it’ll stop automatically after 30s.
iSmartINC 605 Injector Cleaner & Tester
6) Now it can use normally.
Note: if there have no liquid out, you can run it again.
Operating Procedures
Preparation
1) Remove the injector from the engine to check the O-rings inside for damage. If it is be damaged need to
replace it. Put the outside of injector in gasoline or detergent, and wipe them with soft cloth after cleaning
the outside oil sludge carefully.
2) Check the test liquid level to be sure there are enough test liquid inside tank. Pouring test liquid from the
port at the top left side of the unit and watch the liquid level in the fuel level viewer. In most cases, filled the
liquid up to 1/2 of the tank capacity.
Function icon
Function
description
Drain for Ultrasonic
Drain for test tubes