![Smartsafe Tech X-431 ADAS Mobile User Manual Download Page 53](http://html1.mh-extra.com/html/smartsafe-tech/x-431-adas-mobile/x-431-adas-mobile_user-manual_1298224053.webp)
SAFETY
PRECAUTION
INITIAL
USE
ST
ART CALIBRA
TION
TARGET P
ATTERN KIT
PRODUCT PROFILE
ADAS Mobile
Calibration Tool
User Manual
46
www.newsmartsafe.com +86 755 84528537
20. Tap
Complete/Continue
to confirm and end the whole calibration session.
3.2 Calibrating the rear camera
This chapter describes a general operation procedure of rear camera calibration on
AUDI A4 USA/Canada
2016 (Model Year 2018)
.
3.2.1 Why to calibrate?
1). The following diagnostic trouble code is found on the vehicle:
B201000 - Rear view system has not been calibrated.
2). The following repairs and replacements are made on the vehicle:
The backup camera R189 has been removed and installed.
The backup camera system control unit J772 has been replaced.
After the accident repair has been done on the rear body or the trunk lid.
After four-wheel alignment.
After repair work has been made on the front or rear axle.