S140U INSTALLATION

This layout is for a single collector installed near the pool filter equipment. Installing the collector on a roof, rack or fence may require additional
plumbing and hardware kits.

Cool Water
(Feed)

Warm Water
(Return Fitting)

Pool Pump

Elbow Connector

Elbow Connector

White End Cap

White End Cap

Label

Filter

Feed Hose

Return Hose

1) Ensure there is adequate work space to unroll the 20’ collector. 
2) Remove the collector from the box and the strap from around the 

collector. Slowly uncoil the panel. 

Note:

Laying the collector in the reverse direction of the coils will help 

flatten the panel.

3) Remove and discard the black protective caps covering the threaded 

portion of the headers.

4) Wrap the threaded ends of the

headers with the provided Teflon
tape to ensure a watertight seal.

5) Locate the header that does not have

the white serial number label and
install the PVC end caps on either
end of that header.

6) Locate the header with the white

serial number label and install the 
PVC elbow connectors on either end
of that header.

7) Turn the pool pump off and

ensure the handle of the filter
is in the OFF/CLOSED position.

8) Plug the return fitting to

prevent water loss.

9) Remove the flex hose

from the return fitting of
the pool and secure it to
the lower PVC elbow
connector using a stainless
steel clamp.

10) Secure another flex hose (not included) to the top PVC elbow and 

return fitting of the pool using the stainless steel hose clamps 
following the above system layout.

The collector is now installed and ready to use. Ensure that all 
fittings are secure.

11) Remove the plug from return fitting and turn the handle of the 

filter to the FILTER position.

12) Turn the pool pump to the ON position. 

Note:

Air bubbles may come through the return line during initial

start-up of the collector. This is normal and will stop after all the air has
been purged from the solar heating system. 

Summary of Contents for S120U

Page 1: ...www smartpool com INSTALLATION AND OPERATION MANUAL Models S120U S240U Read all instructions before assembling or using the SunHeater system Retain this manual for future use ...

Page 2: ... installing the SunHeater on a roof fence or rack system When installing the collectors near the pool especially on an elevated rack system ensure that the structure does not provide access to the pool Installing the collectors over grass will cause damage to the lawn Do not walk on the collectors Turn off all pool equipment prior to installation Only use SmartPool approved mounting equipment when...

Page 3: ...e 1 S240 U Item Description Qty A 1 5 Stainless Steel Hose Clamp 4 B 3 75 Rubber Hose Connector 2 C PVC Elbow Connector 2 D PVC End Cap 4 E Teflon Tape 1 Note An extra rubber hose has been supplied to connect additional SunHeater systems A x4 B C x2 D x2 E INSTALLATION TOOLS REQUIRED Flathead screwdriver or 5 16 8mm nut driver Plug for return fitting For roof or rack mounting o Power drill o 1 8 3...

Page 4: ...he white serial number label and install the PVC end caps on either end of that header 6 Locate the header with the white serial number label and install the PVC elbow connectors on either end of that header 7 Turn the pool pump off and ensure the handle of the filter is in the OFF CLOSED position 8 Plug the return fitting to prevent water loss 9 Remove the flex hose from the return fitting of the...

Page 5: ...fitting to prevent water loss 9 Remove the flex hose from the return fitting of the pool and secure it to the lower PVC elbow connector using a stainless steel clamp 10 Secure another flex hose not included to the top PVC elbow and return fitting of the pool using the stainless steel hose clamps following the above system layout The collector is now installed and ready to use Ensure that all fitti...

Page 6: ...d the bracket in place as shown Important If installing on a roof use a silicone sealant to prevent water leakage into structure Apply adequate amounts of sealant to both the pre drilled hole and over the screw head once installed 4 Install a bracket on the bottom side of the panel as shown ensuring that the bottom bracket is in line with the top bracket Note 15 brackets are provided with each kit...

Page 7: ... Remove the vacuum relief valve at the top of the solar system Remove the rubber end cap at the bottom and be sure ALL the water is drained out of the system Replace end caps and blow pressurized air in the reverse direction of normal water flow This is the most effective way to drain your system You can leave the collectors in place as long as they are completely drained and they will withstand e...

Page 8: ...ery bill SMARTPOOL INC SHALL IN NO WAY BE LIABLE OR RESPONSIBLE UNDER ANY CIRCUMSTANCES OR IN ANY AMOUNT FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES OR FOR ANY INJURY OR DAMAGES TO PERSON OR PROPERTY USING OR USED IN CONNECTION WITH THIS PRODUCT OR FOR LOSS OF PROFITS OR OTHER COSTS OR EXPENSES OF ANY KIND OR CHARACTER THERE ARE NO OTHER WARRANTIES OR REPRESENTATIONS EITHER EXPRESS OR IMPLIED WHET...

Reviews: