4.0 - Technical data
4.1 - Load capacity
Skylifter can lift and hold a maximum load of:
400 kg
The machine has a dual-circuit vacuum system. Each vacuum circuit can lift and hold the maximum load.
4.2 - Weight
Without mounting bracket and supporting legs
375 kg
Weight of supporting legs (2 x detachable legs)
15 kg
Weight of mounting bracket/adapter:
The weight depends on the type of carrier, with which Skylifter will
be used, see Appendix 1.
4.3 - Physical dimensions when Skylifter is on transportation bracket without
mounting bracket/adapter
Functions folded
Functions extended to max.
Length:
0.80 m
1.48 m
Width (without traverse):
1.20 m
0.88 m
Height:
1.20 m
1.20 m
4.3.1 Physical dimensions on machine without transportation bracket and mounting
bracket/adapter
Functions folded
Functions extended to max.
Length:
0.80 m
1.48 m
Width (without traverse)
0.88 m
0.88 m
Height:
0.80 m
1.00 m
4.4 - Operating time
Maximum operating time is relative and depends on how the machine is used, battery level and ambient
temperature.
At 23
o
C with a new, fully charged battery, the machine's operating capacity is:
4 hours continuous operation with a 400 kg load or
8 hours of 50% operation with a 400 kg load.
If Skylifter is to be used for a longer period of time, we recommend you purchase an extra battery, which can
be replaced in seconds.