background image

  

Instructions for use and maintenance

       

3

HOW TO INSTALL YOUR SMARTHERM HEATER

 WARNING:  All wiring and installation must be 
supervised by a suitably qualified person. 

 WARNING:  Do not install this unit where it may be 
subjected to freezing conditions. 

This electric water heater complies with the requirements 
of EN 60335-1, EN 60335-2-21.

I. 

PURPOSE OF USE

 The appliance is designed to supply hot water to 
household facilities equipped with a piping system 
operating with pressure not greater than 5.5 bars.

It is designed to operate only in closed and heated 
premises where the air temperature is not lower than 
4°C and it is not designed to operate in a continuous 
protracted regime.

II. 

TECHNICAL SPECIFICATIONS

1. 

Nominal volume 10 or 15 litres - see the appliance‘s 
rating plate

2. 

Nominal voltage - see the appliance‘s rating plate

3. 

Nominal power consumption - see the appliance‘s 
rating plate

4. 

Nominal pressure - see the appliance‘s rating plate

 ATTENTION! This is not the water mains pressure. This is 
the pressure that is rated for the appliance and refers to 

the requirements of the safety standards. 

5. 

Water heater type - closed accumulating water heater, 
with thermal insulation

6. 

Inner coating: Glass-ceramic

7. 

Daily energy consumption – see Annex I

8. 

Rated load profile - see Annex I

9. 

Quantity of mixed water at 40°C 10 & 15 litres - see 
Annex I

10. 

Maximum temperature of the thermostat - see Annex I

11. 

Default temperature settings - see Annex I

12. 

Energy efficiency during water heating - see Annex I

III. 

IMPORTANT RULES

 •

Do not switch on the water heater until you are sure 
that it is filled with water.

 •

A suitably qualified person must perform the 
connecting of the water heater to the water supply. 

 •

A suitably qualified electrician must perform the 
connecting of the water heater to the electric network 
(for models without a fitted plug).

 •

Connecting the water heater to the electric mains via 
a plug must only use the plug supplied

 •

If the water-heater will not be used for longer than 
3 days and the temperature in the premises could 
drop below 4°C, the water in the water heater must 
be drained to avoid any possible damage of the 
appliance. (please observe the procedure outlined in 
subsection 2)

 •

During operation, the appliance may produce a 
“hissing” noise (the boiling water). This is normal and 
does not indicate any damage or a fault. This noise 
may increase in volume over time as limescale is 
deposited. To remove the noise, the appliance must 
be de-scaled thoroughly. Failure to de-scale the 
appliance regularly in hard water areas may impair its 
performance and affect the warranty.

 •

For safe operation, the safety return-valve must undergo 
regular cleaning and inspection for normal functioning, 
the valve must not be obstructed, and for the regions 
with hard water it must be de-scaled as necessary. This 
service is not provided under warranty maintenance.

 •

All alterations and modifications to the water 
heater‘s construction and electrical circuitry are 
undertaken entirely at the purchaser’s risk and 
are NOT recommended. 

Any such alterations or 

modifications may invalidate the appliance‘s 
warranty.

 •

Alterations and modifications shall include any 
instances of removal of elements incorporated by the 
manufacturer, building in additional components, 
replacement of elements by those not approved by 
the manufacturer.

 •

If the power cord (of models that have one) is damaged, 
it must be replaced immediately by an appropriately 
qualified person, in order to avoid any risks

Summary of Contents for 10L 2kw OSHW

Page 1: ...ELECTRIC WATER HEATER Instructions for use and maintenance...

Page 2: ...NOTE You may be charged for a service call if you do not have the serial number IMPORTANT SAFETY INFORMATION Your Smartherm Heater has been designed for convenience economy and safety of use provided...

Page 3: ...form the connecting of the water heater to the water supply A suitably qualified electrician must perform the connecting of the water heater to the electric network for models without a fitted plug Co...

Page 4: ...allation We recommend installation of the device close to the likely outlet i e Tap where hot water is used in order to reduce heat losses The selected installation location must be clean and dry at a...

Page 5: ...t stream of water should flow from the watermixing faucet Now you can shut the hot water tap on the mixing area If emptying the water heater you must first cut off the power supply Draining procedure...

Page 6: ...has switched off 5 Regulator knob for temperature setting Water heaters with electrical mechanical POP UP operation 1 Push the knob to pop up Fig 7 2 Set the temperature of the water heater Fig 7b Th...

Page 7: ...e has no effect on the expiry date The guarantee on any exchanged parts or product ends when the original guarantee period ends EXCLUSIONS This guarantee DOES NOT cover damage or defects arising from...

Page 8: ...final energy and or the annual fuel consumption in GJ in terms of GCV rounded to the nearest integer and calculated in accordance with point 4 of Annex VIII 7 the thermostat temperature settings of t...

Page 9: ......

Page 10: ...GCU 10 GCU 15...

Page 11: ......

Page 12: ...CONTACT US Smartherm C D Power Road Plantation Business Park Bromborough Wirral CH62 3RN Tel 44 0 151 355 1094 Email info jouleuk co uk 105442_001...

Reviews: