Instructions for use and maintenance
3
HOW TO INSTALL YOUR SMARTHERM HEATER
WARNING: All wiring and installation must be
supervised by a suitably qualified person.
WARNING: Do not install this unit where it may be
subjected to freezing conditions.
This electric water heater complies with the requirements
of EN 60335-1, EN 60335-2-21.
I.
PURPOSE OF USE
The appliance is designed to supply hot water to
household facilities equipped with a piping system
operating with pressure not greater than 5.5 bars.
It is designed to operate only in closed and heated
premises where the air temperature is not lower than
4°C and it is not designed to operate in a continuous
protracted regime.
II.
TECHNICAL SPECIFICATIONS
1.
Nominal volume 10 or 15 litres - see the appliance‘s
rating plate
2.
Nominal voltage - see the appliance‘s rating plate
3.
Nominal power consumption - see the appliance‘s
rating plate
4.
Nominal pressure - see the appliance‘s rating plate
ATTENTION! This is not the water mains pressure. This is
the pressure that is rated for the appliance and refers to
the requirements of the safety standards.
5.
Water heater type - closed accumulating water heater,
with thermal insulation
6.
Inner coating: Glass-ceramic
7.
Daily energy consumption – see Annex I
8.
Rated load profile - see Annex I
9.
Quantity of mixed water at 40°C 10 & 15 litres - see
Annex I
10.
Maximum temperature of the thermostat - see Annex I
11.
Default temperature settings - see Annex I
12.
Energy efficiency during water heating - see Annex I
III.
IMPORTANT RULES
•
Do not switch on the water heater until you are sure
that it is filled with water.
•
A suitably qualified person must perform the
connecting of the water heater to the water supply.
•
A suitably qualified electrician must perform the
connecting of the water heater to the electric network
(for models without a fitted plug).
•
Connecting the water heater to the electric mains via
a plug must only use the plug supplied
•
If the water-heater will not be used for longer than
3 days and the temperature in the premises could
drop below 4°C, the water in the water heater must
be drained to avoid any possible damage of the
appliance. (please observe the procedure outlined in
subsection 2)
•
During operation, the appliance may produce a
“hissing” noise (the boiling water). This is normal and
does not indicate any damage or a fault. This noise
may increase in volume over time as limescale is
deposited. To remove the noise, the appliance must
be de-scaled thoroughly. Failure to de-scale the
appliance regularly in hard water areas may impair its
performance and affect the warranty.
•
For safe operation, the safety return-valve must undergo
regular cleaning and inspection for normal functioning,
the valve must not be obstructed, and for the regions
with hard water it must be de-scaled as necessary. This
service is not provided under warranty maintenance.
•
All alterations and modifications to the water
heater‘s construction and electrical circuitry are
undertaken entirely at the purchaser’s risk and
are NOT recommended.
Any such alterations or
modifications may invalidate the appliance‘s
warranty.
•
Alterations and modifications shall include any
instances of removal of elements incorporated by the
manufacturer, building in additional components,
replacement of elements by those not approved by
the manufacturer.
•
If the power cord (of models that have one) is damaged,
it must be replaced immediately by an appropriately
qualified person, in order to avoid any risks
Summary of Contents for 10L 2kw OSHW