SmartGauge SmartGuard Owners And Installation Manual Download Page 2

5.

 

Ensure the connections to the relay coil are the correct way round ! Failure to ensure this will result in

the relay having exactly the opposite action to that required.  The terminal marked “REL –“ on the

PCB should be connected to the unmarked coil contact on the relay. The terminal marked “REL+” on

the PCB should be connected to the coil contact marked with a “+” on the relay.

WARNING

 Incorrect connections to any of the terminals may cause permanent damage to the unit which

will not be covered under warranty.

Installation and usage notes

SmartGuard will not allow the reset button to attempt to 

close

 the relay unless it was actually SmartGuard

that 

opened

 it in the first place. For this reason it may be found that, following installation or trouble

shooting (for instance if the relay was installed or supplied in the latched open position) the relay is latched

in the open position and therefore the entire electrical system is shut down. It would seem that there is no

way out of this situation without disconnecting the relay and manually connecting it to the batteries

temporarily to reset it. This is not the case. Simply press the reset switch and HOLD it pressed. After

approximately 6 seconds the LED in the switch will start to blink. Releasing the switch whilst the LED is

blinking will force the relay into the latched closed position.