GP Series
14
©2013 Smarter Tools, Inc. All Rights Reserved
Installation (cont’d)
_________________________________________________________________________________________________
Note:
The E and EB models using an electric starter require a 12V battery with a minimum of 7AH. While
higher Amp Hour batteries may be used, do not attempt to start the engine using a battery rated for a lower or
higher Voltage.
Connect the Battery
1. Remove 10mm bolt from one side of battery securing bracket and move bracket out of the way.
2. Place battery into battery cradle and replace bracket.
3. Remove the protective cover from the positive (red) battery lead.
Positive lead is marked with a “+”.
4. Attach the positive lead to the positive terminal (marked with a “+”) on the battery with the phillips-head cap screw
and secure with 8mm nut.
5. Remove the protective cover from the negative (black) battery lead.
Negative lead is marked with a “-”.
6. Attach the negative lead to the negative terminal (marked with a “-”) on the battery with the phillips-head cap screw
and secure with 8mm nut.
7. The battery will charge when the generator is running with the battery cables attached.
NOTE:
Connecting the battery with reverse polarity will cause damage to the generator.
DO NOT
use the charging cables on the generator battery with battery cables attached.
CAUTION:
PRIOR TO FIRST USING THE GENERATOR, THE
ENGINE MUST BE FILLED WITH HIGH QUALITY SAE
10W-30 GRADE ENGINE OIL.
Add Engine Oil
1. Place the generator on a flat and level surface.
2. Remove oil fill cap/dipstick to add oil.
3. Add high quality SAE 10W-30 grade engine oil.
4. Check engine oil daily and add as needed.