NB40F2
REV 01 – Nov. 2018 - ENGLISH
MAINBOARD
1) Main connector
2) Buzzer
3) Diagnostic LEDs
4) PIR connector
5) DIP Switch
6) Smoke cartridge connector
7) Expansion bus connector
8) Internal siren connector
9) Tamper switch
10) Validation board provided with smoke cartridge
MAIN CONNECTOR
GND:
Ground power supply
+12V:
+10..15VDC power supply
24H
Tamper clear contact
CSI
Immediate smoke delivery (INPUT)
SI
System state (armed/disarmed) (INPUT)
ALL
Alarm (INPUT)
ALL
Alarm (OUTPUT)
PIR
PIR movement detection (OUTPUT)
UNDERVOLTAGE ROTECTION
NUBI 4.0 is protected against under voltage. When the
power supply falls below the 10V threshold, the smoke
emission will be inhibited.
This function prevents unwanted smoke emissions when
NUBI 4.0 and the alarm panel use the same power supply
and the alarm panel causes unwanted commands due to a
low supply voltage.
This could happen during a power failure that lasts a long
time and drains the battery below the 10V limit.
INPUTS INTERFACE
When the DIP Switches 1..4 are set to OFF, NUBI inputs
will become active when switched to GND, as shown in the
following table:
CSI
Trigger the smoke delivery when the input is
closed to GND
SI
Burglar system armed when the input is closed to
GND, disarmed when opened.
ALL
Burglar alarm active when the input is closed to
GND.
With the DIP SW1 the inputs reference can be changed
from GND to +12V (+VCC). Using SW2, SW3, SW4 each
input logic can be switched from normally open to normally
closed as shown the following DIP Switches functional
table.
In the event that the inputs are not driven with a clean
contact to GND,
never apply a voltage higher than
+VCC to the input
which would irreversibly damage the
electronic circuit.
DIP SWITCHES
DIP OFF
ON
1
Input driven to GND
Input driven to +12V (+VCC)
2
CSI input normally open
CSI input normally closed
3
SI input normally open
SI input normally closed
4
ALL input normally open
ALL input normally closed
5
PIR output active low
PIR output active open
6
ALL output active low
ALL output active open.
(Not for internal siren use)
7
Operating mode
Test mode
8
Tamper enabled
Tamper disabled