NB40F2

REV 01 – Nov. 2018 - ENGLISH

MAINBOARD 

1) Main connector
2) Buzzer
3) Diagnostic LEDs
4) PIR connector
5) DIP Switch
6) Smoke cartridge connector
7) Expansion bus connector
8) Internal siren connector
9) Tamper switch
10) Validation board provided with smoke cartridge

MAIN CONNECTOR

GND:

Ground power supply

+12V:

+10..15VDC power supply

24H

Tamper clear contact

CSI

Immediate smoke delivery (INPUT)

SI

System state (armed/disarmed) (INPUT)

ALL

Alarm (INPUT)

ALL

Alarm (OUTPUT)

PIR

PIR movement detection (OUTPUT)

UNDERVOLTAGE ROTECTION

NUBI   4.0   is   protected   against   under   voltage.   When   the
power   supply  falls   below  the   10V   threshold,   the   smoke
emission will be inhibited. 

This function prevents unwanted smoke emissions when
NUBI 4.0 and the alarm panel use the same power supply
and the alarm panel causes unwanted commands due to a
low supply voltage.

This could happen during a power failure that lasts a long
time and drains the battery below the 10V limit.

INPUTS INTERFACE

When the DIP Switches 1..4 are set to OFF, NUBI inputs
will become active when switched to GND, as shown in the
following table:

CSI

Trigger   the   smoke   delivery   when   the   input   is
closed to GND

SI

Burglar system armed when the input is closed to
GND, disarmed when opened.

ALL

Burglar alarm active when the input is closed to
GND.

With the DIP SW1 the inputs reference can be changed
from GND to +12V (+VCC). Using SW2, SW3, SW4 each
input logic can be switched from normally open to normally
closed   as   shown   the   following   DIP   Switches   functional
table.

In the event that the inputs are not driven with a clean
contact  to  GND,  

never   apply  a  voltage  higher  than

+VCC to the input

 which would irreversibly damage the

electronic circuit. 

DIP SWITCHES

DIP OFF

ON

1

Input driven to GND

Input driven to +12V (+VCC)

2

CSI input normally open

CSI input normally closed

3

SI input normally open

SI input normally closed

4

ALL input normally open

ALL input normally closed

5

PIR output active low

PIR output active open

6

ALL output active low

ALL output active open.
(Not for internal siren use)

7

Operating mode

Test mode

8

Tamper enabled

Tamper disabled