background image

USER MANUAL

Longo Modbus Products
LMP-1.CA1M
Card Access module

Version 1

SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: [email protected] / www.smarteh.si

Summary of Contents for Longo Modbus Products LMP-1.CA1M

Page 1: ...USER MANUAL Longo Modbus Products LMP 1 CA1M Card Access module Version 1 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si ...

Page 2: ...Longo Modbus Products LMP 1 CA1M Written by SMARTEH d o o Copyright 2020 SMARTEH d o o User Manual Document Version 1 January 2020 i ...

Page 3: ...include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misconnections may result in device damage fire or personal injury Hazardous voltage in the device can cause electric shock and may result in personal injury or death NEVER SERVICE T...

Page 4: ...P 1 CA1M 1 DESCRIPTION 1 2 FEATURES 2 3 OPERATION 3 3 1 Modbus RTU variables 4 4 INSTALLATION 6 4 1 Connection scheme 6 4 2 Mounting frame selection 8 4 3 Mounting instructions 9 4 4 Module labeling 10 5 TECHNICAL SPECIFICATIONS 11 6 CHANGES 12 7 NOTES 13 iii ...

Page 5: ...code is successfully read out In case key card for correspondent room is valid the green LED blinks again and a short beep is generated Other devices can be activated at this event like door lock opening turning light on If the ID card number is not valid the red LED blinks and a longer beep is generated In case other magnet or contact chip card system is used for door unlock LMP 1 CA1M module can...

Page 6: ...A1M 2 FEATURES Figure 1 LMP 1 CA1M module Table 1 Features RFID reader LEDs for showing activated messages requests occupied do not disturb room service SOS OK LED FAULT X LED Power LED Internal fault LED Internal built in buzzer 2 ...

Page 7: ...an be read out and authenticated If code has appropriate rights main module should activate idCodeOK command If code is not authorized main module application should activate idCodeFault command Regarding command received following action are triggered on module idCodeOK OK LED4 blink short beep idCodeFault FAULT LED3 blink long beep Either command is received or not from main module application w...

Page 8: ...14400 bps 7 19200 bps 8 38400 bps 9 56000 bps 10 57600 bps 11 115200 bps other 19200 bps default 100 mbParityMem Modbus Parity 0 none 1 eve n default 2 odd other none Table 3 3xxxx Input registers Reg Name Description Raw Engineering data 1 iIDW1 RFID ID received word 1 0 65535 0 65535 2 iIDW2 RFID ID received word 2 0 65535 0 65535 3 iIDW3 RFID ID received word 3 0 65535 0 65535 4 iIDW4 RFID ID r...

Page 9: ...aultLedCmd Set Reset Fault LED 0 Reset 1 Set 6 oIDOKLedCmd Set Reset OK LED 0 Reset 1 Set 7 oLedOccupied Set Reset Occupied LED 0 Reset 1 Set 8 oLedDoNotDisturb Set Reset Do not disturb LED 0 Reset 1 Set 9 oLedRoomService Set Reset Room service LED 0 Reset 1 Set 10 oLedSOS Set Reset SOS LED 0 Reset 1 Set 11 oCommToggleBit Communication toggle bit loop 0 1 Table 5 1xxxx Discrete inputs Reg Name Des...

Page 10: ...Longo Modbus Products LMP 1 CA1M 4 INSTALLATION 4 1 Connection scheme Figure 2 Connection scheme 6 ...

Page 11: ...sing or power off LED3 blue Do not disturb On request active Off no request LED4 blue Room service On request active Off no request LED5 red FAULT X On RFID key standard NOK or ID card number wrong Off No tag in proximity LED6 green OK On RFID key standard OK and ID card number valid Off No tag in proximity LED7 blue SOS On request active Off no request LED8 blue Occupied On request active Off no ...

Page 12: ...Idea Tem Modul Soft Modul Line Master Frames of other vendors most probably suits as well but they were not verified by Smarteh Before installation verify compatibility of non listed frames Module housing has a fin on each side which can be easily removed with knife cutter or pliers This adaptation enables housing to be build in various frame formats with two different depths With regard to frame ...

Page 13: ...sed to avoid interference between panels RFID panel should not be positioned close to conductive areas e g metal frames and metal cover plate Mounting instructions 1 Set the correct LMP 1 CA1M settings refer to the Table 2 and Table 8 2 Connect LMP 1 CA1M with appropriate cable to the connector K1 Modbus RTU Master equipment and power supply source refer to Table 6 Max allowed tensile force is 30 ...

Page 14: ... name CCDDD sequence code CC year of code opening DDD derivation code EEE version code reserved for future HW and or SW firmware upgrades 3 S N SSS RR YYXXXXXXXXX serial number SSS short product name RR user code test procedure e g Smarteh person xxx YY year XXXXXXXXX current stack number 4 D C WW YY date code WW week and YY year of production Optional 1 MAC 2 Symbols 3 WAMP 4 Other 10 XXX N ZZZ P...

Page 15: ...tor type RJ 12 6 6 4 6 Power consumption 1 W RFID type ISO IEC 14443 A MIFARE Max reading distance 4 cm Dimensions W x H x D 75 x 49 x 29 mm Weight 40 g Ambient temperature 0 to 50 C Ambient humidity max 95 no condensation Maximum altitude 2000 m Mounting position horizontal Transport and storage temperature 20 to 60 C Protection class IP 20 11 ...

Page 16: ...Longo Modbus Products LMP 1 CA1M 6 CHANGES The following table describes all the changes to the document Date V Description 10 01 2020 1 The initial version issued as LMP 1 CA1M module UserManual 12 ...

Page 17: ...Longo Modbus Products LMP 1 CA1M 7 NOTES 13 ...

Reviews: