SmartDHOME 01335-2085-00 User Manual Download Page 3

MyMB interface/actuator for ModBus systems 

User manual and data sheet

 

 

Rev. 3 del 02.12.2022 

Pag.  3/18 

 

human health safety. Recycling materials helps conserve natural resources. For further information, contact 
the municipal office in your area, the waste collection service or the center where you purchased the product. 

 

Disclaimer 

 

SmartDHOME Srl cannot guarantee that the information regarding the technical characteristics of the devices 

contained in this document are correct. The product and its accessories are subject to constant checks aimed 

at improving them through careful analyzes and research and development activities. We reserve the right to 

modify  the  components,  accessories,  data  sheets  and  related  product  documentation  at  any  time,  without 

notice. 

Sul sito 

www.myvirtuosohome.com/en/

 le documentazioni saranno sempre aggiornate. 

 

Intended use 

 

This  device  has  been  designed  for  monitoring  the  performance  of  systems  such  as  heat  pumps  or  hybrid 

inverters that communicate via the ModBus protocol. In the event of improper use and/or modifications not 

authorized by our technical department, the company reserves the right to cancel the two-year guarantee and 

to provide assistance upon payment of the service. 

 

Description 

 

The MyMB interface/actuator for ModBus systems is a fundamental tool for achieving predictive maintenance, 

adaptive  energy  management,  qualitative  data  analysis  and  remote  parameter  programming  objectives  for 

correct system operation. It has communication capabilities both through a Sigfox M2M network, through a 

gateway equipped with a transceiver with Z-Wave protocol, and through Wi-Fi. 
Through these protocols it will be possible to send the information received to a big data management cloud 
system  to  evaluate,  through  a  predictive  maintenance  process,  the  implementation  of  automatic  customer 
support processes. 

 

Summary of Contents for 01335-2085-00

Page 1: ...ace actuator for ModBus systems the latest generation device that allows you to monitor the performance of systems such as heat pumps or hybrid inverters that communicate via ModBus protocol Z Wave ce...

Page 2: ...Contact the assistance network if one or more of the following conditions occurs on the product and or an accessory supplied or optional a If the product has come into contact with water or liquids b...

Page 3: ...empre aggiornate Intended use This device has been designed for monitoring the performance of systems such as heat pumps or hybrid inverters that communicate via the ModBus protocol In the event of im...

Page 4: ...o 30 m in open field Heat pump compatibility NOTE Every week we integrate new brands to stay up to date visit the product page on the site https www smartdhome com en projects iot devices iot connecte...

Page 5: ...ator for ModBus systems FIGURE 1 Buttons and LEDs Functions button see Wi Fi configuration and Z Wave configuration Reset button restart the device Connections To make the connections and operate the...

Page 6: ...can connect the device to the system in your home Below are some useful tips for pre installing the device 1 Pay close attention to the polarity of the ModBus connection 2 Pay close attention to the...

Page 7: ...achable etc Compatible devices SmartDHOME The MyMB can be connected to multiple devices in our catalog so that the latter can interface with the MyVirtuoso Home building automation system All the devi...

Page 8: ...r with slam shut valve and ModBus interface 01340 1010 00 MyGMSI G6 0 membrane gas meter with slam shut valve and ModBus interface 01340 1015 00 MyGMSI G10 0 membrane gas meter with slam shut valve an...

Page 9: ...n the button is released the device will enter configuration signaling the status with an alternate flashing of the LEDs red and green This will create the IoB Wi Fi to which you will need to connect...

Page 10: ...twork with SSID IOB no passkey required 5 Once the connection is established open the navigation application and enter the following link and press enter http 192 168 4 1 sethost host iobgw contactpro...

Page 11: ...MyMB power supply Output for powering the ModBus device RS 485 interface ModBus Brown Blue Black Red Yellow Green 12 Vdc Input GND GND 24 Vdc Output ModBus A ModBus B NOTE For further explanations re...

Page 12: ...er supply Uscita per l alimentazione del dispositivo ModBus Interfaccia RS 485 ModBus Brown Blue Black Red Yellow Green 12 Vdc Input GND GND 24 Vdc Input ModBus A ModBus B NOTE For further explanation...

Page 13: ...MB power supply Output for powering the ModBus device RS 485 interface ModBus Brown Blue Black White Blue Brown 12 Vdc Input GND GND 24 Vdc Input ModBus A ModBus B NOTE For further explanations regard...

Page 14: ...tems it must be included in the MyVirtuoso Home network NOTE For the inclusion and exclusion procedure see the Z Wave configuration paragraph above After completing the device inclusion procedure foll...

Page 15: ...e see point 2 and then click on the icon to be able to modify the library and if present also the ModBus address 4 Select the desired ModBus library and if present also the ModBus address NOTE To retr...

Page 16: ...t been implemented It is therefore recommended to use the CC COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_SWITCH_BINARY This CC can be used to turn the boiler on off or to know its current status It also...

Page 17: ...hich are obtained from the heat pump Parameter number dec Parameter Bytes Mode 90 ID 4 Read 91 Version 2 Read 92 Modbus address 2 Read Write 93 Modbus library 2 Read Write 1 Max setpoint of the boiler...

Page 18: ...chain damaging our health and well being When replacing old appliances the dealer is legally obliged to take back the old appliance for free disposal Warranty and customer support Visit our website at...

Reviews: