SMART PLT600 User Manual Download Page 3

1.

- This is a switch to turn “ON” or “OFF” the machine supply.

ON/OFF SWITCH

2.

- This is a toggle switch for selection betwwen “PLT” or “HRD”

PLT/HRD SWITCH

test selection.

3.

- This is a toggle switch for selection between “setting mode”

SET/RUN SWITCH

or “run mode”.

4.

- It is a LED indication for showing Test Result.

RESULT LED

“Green LED” means test result is “Pass” and the battery is GOOD,
“Red LED” means test result is “Fail” and the battery is BAD.

5.

- During RUN mode It shows 3 Digit value of Test Current.

CURRENT DISPLAY

6.

- During RUN mode it shows 4 Digit value of battery voltage.

VOLTAGE DISPLAY

During SET mode it shows the 4 Digit value for Cutoff Voltage.

7.

- During RUN mode for PLT TEST it is a Down Timer in Seconds.

TIMER DISPLAY

During RUN mode for HRD TEST it is a UP Timer from zero.

8.

- This is a LED indication for Timer (only during HRD TEST mode).

HH:MM LED

LED is “ON”, it means timer is showing time in Hours and Minutes.
LED is “OFF”, it means timer is showing time in Minutes and Seconds.

9.

- This is a push button type keypad having 3 keys.

KEYPAD

1. UP key         2. DOWN key        3. ENTER/START key

10.

- This is a pickup wire connection for voltage measurement

VOLTAGE VE

from +VE battery terminal.

11.

- Aluminium terminal for connecting heavy load wire pickup

CURRENT VE

from +VE battery terminal.

12.

- This is a pickup wire connection for voltage measurement

VOLTAGE PICKUP -VE

from -VE battery terminal.

13.

- Aluminium terminal for connecting heavy load wire pickup

CURRENT PICKUP -VE

from -VE battery terminal.

14.

- Front mounted fans for forced air cooling of machine.

COOLING FAN

Reviews: