Smart Power
®
Systems
A. C. MODULAR GENERATOR SYSTEM
Page 13 of 53
shaft. Contact the PTO manufacturer and/or the drive shaft manufacture for
installation instructions for remote mounting a hydraulic pump.
4.
Verify that the drive shaft selected will couple to both the PTO and the SPS
supplied pump. Pumps supplied by Smart Power
®
Systems for this system have an
SAE C, 1.25” keyed shaft.
WARNING:
The installer must provide guarding to prevent damage to the pump seals from road
debris. Also, properly sized and installed vibration isolators must be used if the
pump is mounted to the chassis. Failure to do
either will void the system’s
warranty.
Never use an unbalanced drive shaft to drive a remotely located pump. An
unbalanced drive shaft will cause premature wear of the pump and will void the
system’s warranty.
Do not approach a running A.C. modular generator when wearing long, loose items
such as hair, jewelry, ties, clothing, etc. Direct contact with a rotating drive shaft
can cause serious personal injury and/or damage to the system.
5.
Obtain the following hoses of the necessary length for the installation:
a)
Pump inlet hose: 1” SAE 100R1AT-16 hose with Parker hose ends P/N 10643-
16-16.
Note:
Maximum hose length is 20’.
b) Pump outlet hose:
1/2” SAE 100R9AT-8 rated to
4000 PSI
(use Parker hose
ends, part number 10643-8-8).
Note:
Maximum hose length is
20’.
c)
Pump case drain hose: 5/8” SAE 100R1AT-10 (use Parker hose ends, part
number 10643-10-10).
Note:
Maximum hose length is 20’.