SMART MAX GEOSYSTEMS CO.,LTD
www.smartmaxgeosystems.com [email protected]
22
Laser Orientation Measurement.
Steps as bellows
:
1.Leveling the instrument, then power on.
2.Aim at the target through the horizontal Tangent & Clamp
Screws.Turn on the laser.The other points can be found out with a
board which can make the laser focus together.
7.2 Angle Designment
Angle Designment is based on the line of two points,then
design a horizontal angle according with the requirement.
Steps as bellows
:
1.Leveling the instrument, then power on.This must be done on a
fiducial point.
2.Aim at another fiducial point carefully,and set the horizontal
angle as
0°00′00″.
3.Move the telescope to make the horizontal angle be the required
value.Turn the laser on,the laser and the fiducial line will make
up an angle.
7.3 Zeith Measurement
Set a point as a standard, the laser will be set up vertically,this
is
Zeith Measurement.
Steps as bellows
: