10. Allow unit to run two (2) minutes to
warm-up before plugging in any
electrical cords to the generator
outlets.
NOTE: This engine is equipped with a
“Low Oil” shutdown system for engine
protection. The engine stops when the
oil level gets too low. The engine will
not restart without adding oil. Refer to
Preparing the Generator; Engine Fuel
Capacity for instructions on adding oil.
NOTE: While the engine is idling, the
generator voltage is automatically
reduced to reduce generator
temperatures. The voltage will return
to normal levels immediately upon the
application of load.
SHUTDOWN
1. Remove all load by turning off
electrical appliances and unplugging
all
electric cords from the generator.
2. Allow engine to run at idle speed to
cool for two (2) minutes.
NOTE: Failure to allow the engine to cool
at idle for two (2) minutes may result in
damage to the generator.
3. Turn the starter key to the OFF
position. (counter clockwise)
4. Close the valve on the propane
tank or natural gas outlet.
Maintenance
GENERATOR MAINTENANCE
See HONDA Owner’s Manual for
more information.
EVAPORATIVE EMISSION
COMPONENTS:
The unit you have purchased includes
the following components that are in
compliance with 2008 California Air
Resources Board Evaporative
Emission
Standards;
1. Fuel Hose
2. Fuel Hose Fittings
These components should be
inspected on a daily basis for cracks,
leaks, and abnormal wear. If cracking,
leaks or abnormal wear has occurred,
the components should be replaced
immediately.
ENGINE:
The engine for this generator is
governed to operate at speeds close
to 3600 RPM (60Hz) throughout the
operating load range. The no load
speed (before a load is applied) will
be just a bit higher than the load
speed and is normally set to 3750
RPM.
DO NOT TAMPER WITH THE GOVERNOR
MECHANISM, CHANGE THE SETTING
EXPERIMENTALLY, OR PUSH THE
THROTTLE OPEN IN AN ATTEMPT TO
GENERATE MORE ELECTRICAL
CURRENT; EQUIPMENT DAMAGE OR
PERSONAL INJURY MAY RESULT.
CHECKING ENGINE OIL:
Check oil level before each operation
and ensure that it is maintained per
Preparing the Generator;
See
HONDA Owner’s Manual for more
information.
CHANGING ENGINE OIL:
See HONDA Owner’s Manual for
more information.
AIR CLEANER:
See HONDA Owner’s Manual for
more information.
CLEANING AND GAPPING SPARK
PLUG:
See HONDA Owner’s Manual for
more information.
MAINTENANCE SCHEDULE:
See HONDA Owner’s Manual for
more information.
4